listen-in Mode

INstaLLer’s dIaGNOstICs. 
apply  a  shorting  link  to  J6  to  enable  Listen-in 
mode.
all dialler activity will be heard via the onboard 
piezo sounder.

Test Calls

SecurityGuard II:

 test calls are sent weekly to the 

central station. the time interval is fixed.  the first 
test call is sent 14 hours after leaving program 
mode or after powering up the radio dialler.

SecurityGuard III:

 test calls can be programmed in 

intervals 1 day, 7days, 14 days, 30 days or OFF.

Remote Programming

the radio dialler can be programmed remotely 
via PC and Ness upload/download software.
remote programming can used either to:
a/  reset  the  One  shot  programming  option 
allowing the technician to reprogram the radio 
dialler via the securityGuard.
b/  Or  the  phone1,  phone2  and  client  numbers 
can be remotely downloaded to the radio dialler. 
Note, in this case, the numbers programmed in 
the securityGuard may be different to the radio 
dialler.

reMOte PrOGraMMING 
1.  ensure radio dialler is powered up.
2.   Power  up  sGIII  and  press  OFF  to  enter 
PrOGraM mode. radio dialler will now be ready 
to answer incoming calls for the next 5 minutes. If 
the dialler answers a call but does not verify within 
30 seconds it will hang-up. Once a connection is 
established, the dialler will unconditionally hang-
up after 5 minutes if a hang-up is not requested 
sooner by the remote end.
3.   Once a connection is established, program 
the sGIII/radio dialler system as required.

sGIII  will  exit  PrOGraM  mode  when  the  up/
down  connection  is  terminated,  or  when  the 
sGIII PrOGraM mode timer expires, whichever 
occurs first. If PHONe1 has been programmed, 
then if data transfer to radio dialler has not been 
successful within a short period, sGIII will raise 
a system alarm indicating radio link failure with 
the dialler.

Dialling Method

the radio dialler auto-detects the dial tone and 
dials  in  dtMF  or  rotary  as  determined  by  the 
dial tone.
In cases where the dial tone is undetectable or 
non-standard  (such  a  stutter-tone)  the  radio 
dialler can be forced to dial in dtMF always.
Place  a  shorting  link  across  pins  2  &  3  of  the 
J7  header  on  the  main  board  to  force  dtMF 
dialling.

Place a shorting link on 
pins 2 & 3 of J7 to force 
dtMF dialling.

SecurityGuard Supervision

the  integrity  of  the  radio  link  between  the 
securityGuard  and  the  radio  dialler  is  tested 
by a supervision poll sent by the securityGuard 
every 90 minutes. 
If the radio dialler fails to receive eight consecutive 
poll messages it will send a radio Jamming alarm 
to the central station (Contact Id 355-105). 
a restore message is sent when the radio dialler 
receives the next valid poll. 

Place a shorting link on J6 
to enable Listen-in Mode.

Radio PIR Supervision

supervised  detector  (380)  sensor  trouble 
message including the device number is sent the 
sGIII fails to see 24 consecutive polls from the 
device. the restore will be sent when the device 
a poll message or is next triggered.

Содержание 100-284

Страница 1: ...warning Low Battery Battery Missing Battery Capacity tests and warning Telephone Line supervision Fast easy installation No special tools required Compatible with SecurityGuard II III Installation Notes Ness Radio Dialler Part No 100 284 Hybrid Wireless Landline dialler for Ness SecurityGuard systems ...

Страница 2: ...s the alarm data via a telephone landline The Ness SecurityGuard III SGIII has the required radio interface built in whilst the SecurityGuard II SGII can easily be retro fitted with the optional radio interface The Ness Radio Dialler is designed to easily plug into an existing telephone wall socket and does not need to be installed by a licensed telecommunications cabler The result is full back to...

Страница 3: ...ephone connection The Ness Radio Dialler should be connects to an existing telephone wall socket preferably the first incoming telephone socket The existing telephone s lead connects to the Radio Dialler s LINE socket and the supplied telephone cable is used to connect the Radio Dialler to the existing telephone FIG1 Connection Diagram Australia Radio Dialler Unit Mounting Point Power In Battery C...

Страница 4: ...ler s LINE socket See FIG1 5 Connect the supplied telephone cable to the Radio Dialler s TELEPHONE socket and the existing telephone s LINE socket 6a Connect the AC adaptor lead into the power socket on the rear of the Radio Dialler Plug the AC adaptor into a mains outlet and turn mains power on 6b Connect the backup battery to the battery socket inside the battery well 7 On power up the indicator...

Страница 5: ...pacity The battery should be replaced A LOW BATTERY alarm will be reported to the central station A LOW BATTERY RESTORE will be reported when the battery has recharged to approx 75 capacity Flashing Double Flash The backup battery cannot be charged or cannot hold a charge The battery should be replaced On Receiving a valid programming message such as the Learn message from an SGIII Flashing Slowly...

Страница 6: ...Once a connection is established program the SGIII Radio Dialler system as required SGIII will exit PROGRAM mode when the Up down connection is terminated or when the SGIII PROGRAM mode timer expires whichever occurs first If PHONE1 has been programmed then if data transfer to Radio Dialler has not been successful within a short period SGIII will raise a system alarm indicating radio link failure ...

Страница 7: ...er 137 106 137 106 Sensor tamper by device 383 352 400 383 352 400 Panic by user 120 301 350 120 301 350 Duress by user 121 401 450 121 401 450 Medical Pendant 100 651 700 101 651 700 Radio Jamming 355 105 355 105 Radio Device Supervision Poll Fail Detectors 355 202 250 355 202 250 Radio Device Supervision Poll Fail Fixed Panic Button 355 501 600 355 501 600 Dialler Radio Supervision Poll Fail 355...

Страница 8: ... or otherwise without the prior written permission of Ness Ness reserves the right to make changes to features and specifications at any time without prior notification in the interest of ongoing product development and improvement 2008 Ness Security Products Pty Ltd ABN 28 069 984 372 Specifications RX Type SAWR stabilised Bandwidth 3dB 800kHZ Operating Voltage 17V AC plug pack supplied Quiescent...