U service manual
Version 1.2 en
18
O P E R A T I O N
6 Emptying mode
(evaporing)
1)
Switch on machine
2)
Remove the water
tank
3)
Open the slider
4)
Press and hold the
Ristretto and
Lungo controls
together for at
least 6 sec. The
other control
flashes for confir-
mation
5)
Close the slider to
start the procedure
1)
Starts pump
2)
Stops pump after
10 sec
3)
Heats up thermo-
block to 105 °C
(100% power)
4)
Switches off ther-
moblock
5)
Switches off
machine
6)
Blocks machine for
10 min
Switch off machine
7 Resetting mode
• Switch on machine
• Press and hold the
Espresso and Lungo
controls
together for
at least 4 sec. The
other control
flashes
for confirmation
• Resets programmed
volumes to factory
settings (Ristretto
25ml, Espresso
40ml, Lungo 110ml)
• Reset also the auto-
matic off mode to
9 min + the most
frequently used cup
size to espresso.
Proceeds with self test
mode automatically
8 Auto switch off mode
(factory setting of 9 min
can be changed to
30 min)
Automatically after a
certain period of non-
use
• Switch off machine
after 9 min resp.
30 min if no coffee is
brewed or 9 min
resp. 30 min after
last brewed coffee
9 Failure mode
Automatically by fol-
lowing failures:
a) NTC short circuit
b) NTC not connected
c) Heat up too slow
Machine indicates fail-
ure with blinking coffee
buttons as long as the
failure is present
When failure is fixed
Machine mode
Enter mode
Actions
Exit mode
All manuals and user guides at all-guides.com