background image

Executive device Radio 8113 IР65 

Passport 

1

.

Purpose

The executive device Radio  8113  IP65  is  designed  to  control
roller shutters, roller blinds, gate and barrier control units, sun
blinds,  as well  as lighting  devices  and  with  any  other  electric
load

 

with a current consumption of up to 3

 

A using the

remote controls of the Radio series.

187-253/50
20
3 (at cos=1)
1
433.05-434.79
1000
80x80x50
from -30 to +50
0,75
IP65

2

.

Specifications

Supply voltage range, V~/Hz
Consumption current, mA, not more than
Maximum allowable switching current, A
Number of controlled electric drives
Operating frequency range, MHz
Number of recordable codes of remote controls
Overall dimensions, mm
Operation temperature range, °С
Section of interconnecting wires, mm

2

Degree of enclosure protection
Protection class against electric shock

II

The  product  is  not  intended  for  installation  and  operating  in  explosion  hazard  and  fire 
hazardous zones and does not require the protective earth. 

3. Peculiarities

- availability of potential-free contact for connection to automation of other manufacturers;
- control using the remote controls of the Radio series;
- retransmission of commands from dynamic remote controls;
- auto closing timer for rolling gates;
- emergency control of roller shutters, rolling gates.

4. Connection

Use wires with a cross-section of at least 0.75 mm

2

 in double insulation to connect the device

to the network and to the electric drive.

It is prohibited to use mounting wires and cables with polyethylene insulation or sheath. 

It is prohibited to install the device at a distance less than 1 m from heating devices. 

The holes in feedthrough plate should be punctured using a tool

 

of smaller diameter than the 

input cable. 

 

 

 

It is prohibited to supply 220-230

 

V~ voltage to the terminals 8-15. 

To consider 220

 

V~ as the nominal network voltage when delivered to Ukraine. 

It is allowed to change the safeguard on the 5A rating when connecting the drives 

with a current consumption more than 3

 

A. 

5

. Programming of remote controls

Action 

Indication 

1. Input the device in programming mode of remote controls (PM of remote controls)

Press and hold the programming button for more than 4 sec

.

Visual indicator blinks red

.

2. Record the remote control channel in the memory of the device (PM of remote
controls)

Radio 

8101-1M 

a) in dynamic mode: press and hold the
remote control button for more than 2 sec.;
b) in static mode: press short the remote
control button (less than 1 sec.)

When recording the visual 
indicator blinks short-long-
short green light. 

If the remote control is 
already recorded, the 
indicator will flash green 
shortly. 

Radio 

8101-2M 
8101-4M 

a) in dynamic mode: press and hold the
recordable

 

remote control button, and press

short any other;
b) in static mode: press short the recordable
button.

Antenna 

Safeguard 

Power supply 
220- 230

 

V~

Fig. 1 Drive connection

 

Electric drive 

Jumper 220-230

 

V~ 

Visual 
indicator 

Two-button 
switch 

“Programming” button 

General/ground 

Safety inputs 
General/ground

Power  12 V/200 mA 

Содержание Radio 8113 IР65

Страница 1: ...and to the electric drive It is prohibited to use mounting wires and cables with polyethylene insulation or sheath It is prohibited to install the device at a distance less than 1 m from heating devices The holes in feedthrough plate should be punctured using a tool of smaller diameter than the input cable It is prohibited to supply 220 230 V voltage to the terminals 8 15 To consider 220 V as the ...

Страница 2: ...y of the device PM of remote controls Press and hold the programming button for more than 4 sec The visual indicator will flash red for a long time twice 5 Output the device from the PM of remote controls Press short the programming button The visual indication stops The device is automatically removed from the programming mode if no actions are performed with it during 32 sec 6 Operation modes Th...

Страница 3: ...epeatedly the device in the PM of operation mode if it is necessary 2 press and hold the programming button for more than 4 sec The visual indicator will flash yellow after 1 and 4 sec and then it will continue to blink double green light 6 Output the device from the programming mode Press twice shortly the programming button The visual indication stops The device is automatically removed from the...

Страница 4: ...d the device will execute the DOWN command the control from the remote controls and key switch will be blocked when the contact is opened the device will execute the UP command the control from the remote controls and key switch will be available after power re supplying when the contact is opened the device will execute the UP command after power re supplying when the contact is closed the device...

Страница 5: ...ec Retransmission of remote control marking is carried out only together with the control of power relay 8 1 Turning on off the retransmission function Action Indication 1 Input the device in programming mode of repeater from the standby mode Press and hold the programming button for more than 8 sec Visual indicator blinks green for certain times 2 Change the operation mode of repeater Turning on ...

Страница 6: ... or green but the voltage is not supplied on drive a the jumper between terminals 6 and 7 is not installed b the jumper between terminals 6 and 7 is not clamped well a install the jumper between terminals 6 and 7 b clamp the jumper between terminals 6 and 7 The device is not entered in the programming mode a latching switch is connected and the button of one of directions is pressed a change the l...

Отзывы: