background image

 

11 

www.nerival.fi

 

Button functions 

 

 

 

 

The door operator has a self-learning process when it is turned on or a new 

setting is made. The door operator drives the door in its closing direction and 

stops it when the door is closed in the correct position. 

If the device cannot detect the correct stop position, the error message "E08" 

is displayed. 

 

If the door closes in the wrong direction, see setting no. 9. 

 

To skip the self-learning process, press the 

 button to enter the setting 

mode. 

 
 

 

 

 

 

 

 

 :  Scroll up the settings 

 

Option- :  Scroll down the settings 

 

Parameter- : Increase parameter 

 

Pa : Decrease parameter 

 

Save: Save setting / Exit 

Содержание NEO-80

Страница 1: ...1 www nerival fi User manual AUTOMATIC DOOR OPERATOR NEO 80...

Страница 2: ...operator 6 Outward opening door Installation with push arm door operator inside 7 Inward opening door Installation with pull arm door operator inside 8 Connection 9 Button functions 11 Settings 12 Gen...

Страница 3: ...ctrical connections Make sure the power supply is turned off before making any connections This product must be earthed Before turning on the power Ensure correct supply voltage 230VAC Make sure that...

Страница 4: ...4 www nerival fi Overview Automatic door operator Accessories Dimensions...

Страница 5: ...justable Opening angle 0 99 adjustable Supply voltage 230VAC Max power 45W Standby power consumption 2W Remote control distance Over 30m Operating temperature 20 55 Protection class IP12D Dimensions 5...

Страница 6: ...6 www nerival fi Installation example Installation of mounting plate and door operator...

Страница 7: ...fi Outward opening door Installation with push arm door operator inside Loosen the screws to set the push arm at a 90 degree angle to the door Adjust the limit block in the correct position when the...

Страница 8: ...8 www nerival fi Inward opening door Installation with pull arm door operator inside...

Страница 9: ...Double door synchronization Synchronization of two door operators COM COM Sensor power supply Sensor output 12VDC Sensor power supply Sensor output 12VDC Sensor signal Sensor signal input Sensor signa...

Страница 10: ...he input is active the display shows F3 Access control signal COM Signal opens the door from access control The input is either a voltage signal of 12VDC or a short circuit signal When the input is ac...

Страница 11: ...door is closed in the correct position If the device cannot detect the correct stop position the error message E08 is displayed If the door closes in the wrong direction see setting no 9 To skip the...

Страница 12: ...greater the angle at which the door closes slowly 7 Closing force 0 10 8 The higher the value the greater the closing force 8 Type of electric lock 0 3 0 0 magnetic lock 1 electric lock 2 fail safe e...

Страница 13: ...value the slower the minimum speed 24 Damping compensation 0 4 1 The higher the value the higher the damping force 25 Deceleration ramp 0 5 2 The higher the value the greater the slope 26 Opening angl...

Страница 14: ...rol Adding a remote control 1 Go to setting no 10 and press the parameter increase or decrease button 2 Press any key on the remote control 3 The value of the digital display increases by 1 4 The remo...

Страница 15: ...ls disabled Error code Cause Solution E0 System error Replace the controller E1 The motor is not connected Check motor connection E2 Motor line failure Check motor connection replace the motor E3 No m...