background image

 

www.nerival.fi

 

Technical information 

Model 

NEO-1000 

Door max. weight 

100kg 

Door max. width 

1200mm 

Weight 

6kg 

Service life 

More than 3.000.000 operations 

Installation method 

Surface mounting 

Voltage output for locking 

12VDC 

With included relay card  

12V AC/DC - 30V AC/DC 

Door hold-open time 

0-99s, adjustable 

Opening angle 

45°-180°, adjustable 

Supply voltage 

230VAC 

Max. power 

45W 

Standby power consumption 

< 2W 

Remote control distance 

Over 30m 

Operating temperature 

-40

 - 85

 

Protection class 

IP41 

Dimensions 

580mm x 80mm x 90mm 

 

Approvals 

 

 

EU Directive 

Test Standard(s) 

2011/65/EU 

(RoHs) 

EN 62321-1:2013 
EN 62321-2:2014 
EN 62321-3-1:2014 
EN 62321-4:2014+A1:2017 
EN 62321-5:2014 
EN 62321-6:2015 
EN 62321-7-1:2015 
EN 62321-7-2:2017 
EN 62321-8:2017 

EU Directive 

Test Standard(s) 

2014/30/EU 

(EMC) 

EN IEC 61000-6-1:2019 
EN 61000-6-3:2007/A1:2011 
/AC:2012 

Содержание NEO-100

Страница 1: ...1 www nerival fi User manual AUTOMATIC DOOR OPERATOR NEO 100...

Страница 2: ...operator 6 Outward opening door Installation with push arm door operator inside 7 Inward opening door Installation with pull arm door operator inside 8 Kytkent 9 Button functions 11 Settings 12 Gener...

Страница 3: ...ctrical connections Make sure the power supply is turned off before making any connections This product must be earthed Before turning on the power Ensure correct supply voltage 230VAC Make sure that...

Страница 4: ...4 www nerival fi Overview Automatic door operator Accessories Dimensions...

Страница 5: ...ngle 45 180 adjustable Supply voltage 230VAC Max power 45W Standby power consumption 2W Remote control distance Over 30m Operating temperature 40 85 Protection class IP41 Dimensions 580mm x 80mm x 90m...

Страница 6: ...6 www nerival fi Installation example Installation of mounting plate and door operator...

Страница 7: ...7 www nerival fi Outward opening door Installation with push arm door operator inside Loosen the screws to set the push arm at a 90 degree angle to the door...

Страница 8: ...8 www nerival fi Inward opening door Installation with pull arm door operator inside...

Страница 9: ...L Electric lock output 12VDC L Electric lock output 12VDC GND Voltage output 12VDC 12V Voltage output 12VDC max 500mA P1 Voltage signal 12VDC GND GND P1 Door open signal P2 Door close signal P3 Closin...

Страница 10: ...Door close signal The door does not open when the signal is active P3 GND Safety sensor for closing door When the sensor detects the door opens P4 GND Safety sensor for opening door When the sensor de...

Страница 11: ...door is closed in the correct position If the device cannot detect the correct stop position the error message E08 is displayed If the door closes in the wrong direction see setting no 9 To skip the...

Страница 12: ...has opened 6 Closing door anti collision delay 0 30 10 The smaller the delay the faster the door opens in a collision 7 Closing force 0 10 5 The higher the value the greater the closing force 8 Lock...

Страница 13: ...l remote controls Advanced settings Press the button for five seconds to enter the advanced setting mode Use the and buttons to select the setting you want to set Press the decrease or increase button...

Страница 14: ...ter increase or decrease button 2 Press any key on the remote control 3 The value of the digital display increases by 1 4 The remote control has been successfully added Repeat the above steps to add m...

Страница 15: ...over current Check that the electric lock is not short circuited and the current does not exceed 1A E4 Too high DC voltage Check 12V voltage port input and lock E5 Too low DC voltage Check 12V voltage...

Отзывы: