29
Installation Manual
Saturn Bm
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
TB1
TB2
2
6
9
5
1
4 1
4
TB1
OPEN
OPEN
OPEN
OPEN
To
MCU
EXT I/O
(J10)
EXT-A
EXT-B
12V FUSED
Message
Indicator
+12V
EXT I/O
CONNECTOR J10
To TB1 on next
Message Indicator Unit and/or Distress Alarm Unit
(if used)
To TB1 on next
Message Indicator Unit
and/or
Distress Alarm Unit
(if used)
Red
Blue
Green
Yellow
5 4 3 2 1
9 8 7 6
(J10)
EXT I/O
TB1
TB2
Setting 1
Switches 1 and 4
are set to OPEN
Side view of switch 1 (OPEN)
Setting 2
Switches 2 and 4
are set to OPEN
Setting 3
Switches 1, 2 and 4
are set to OPEN
Setting 4
Switches 3 and 4
are set to OPEN
Message Indicator
SATURN B
DATA MESSAGE
TELEX MESSAGE
FAX MESSAGE
INSTALLATION
The Message Indicator Units (max. 4) are connected to the
EXT I/O (J10) outlet located on the rear panel of the MCU.
See diagram for pin configuration.
Message Indicator Unit
Each Message Indicator Unit must have its own
unique switch setting.
The setting is done with the DIP switch inside
the Message Indicator Unit as shown in the
figure. No other combinations are allowed.
For corresponding programming of the MCU,
see "Various Configurations" in the Saturn Bm
Operator's Manual.
Total number of units:
Message Indicator and Distress Alarm
- max 11
Message Indicator
- max 4
Содержание Saturn BM Marine
Страница 1: ...Saturn Bm Marine Class 2 Installation Manual...
Страница 55: ......