![Neptune TRU/FLO Скачать руководство пользователя страница 34](http://html1.mh-extra.com/html/neptune/tru-flo/tru-flo_installation-and-maintenance-manual_1668257034.webp)
Maintaining the TRU/FLO Compound Meter
22
TRU/FLO Compound Meter Installation and Maintenance Guide
7
Use pliers to remove the magnet drive assembly. See Figure 33.
Figure 33 Removing the Magnet Drive Assembly
8
Inspect the o-ring on the calibration vane assembly. If the o-ring on
the calibration vane assembly is nicked or damage, it must be
replaced.
Figure 34 Replacing the O-ring
Replacing the Turbine Measuring Assembly
To replace the turbine measuring assembly, complete the following
steps.
1
Before proceeding, inspect the magnet drive assembly. If it has
been cracked or damaged, replace the magnet drive assembly.
See Figure 35. A replacement drive assembly is available in the
magnet drive assembly kit.
2
Return the calibration vane assembly to the turbine measuring
assembly.
3
Install the calibration vane so that the large portion of the vane is
inside of the measuring assembly.
4
Replace or re-install the magnetic drive assembly.
Figure 35 Magnet Drive Assembly
The magnet drive assembly can be reused if it is not damaged.
Drive assembly
O-ring
Содержание TRU/FLO
Страница 2: ......
Страница 3: ...TRU FLO Compound Meter Installation and Maintenance Guide...
Страница 8: ...Notes Contents vi TRU FLO Compound Meter Installation and Maintenance Guide...
Страница 12: ...x TRU FLO Compound Meter Installation and Maintenance Guide Notes Tables...
Страница 42: ...Why Maintenance is Important 30 TRU FLO Compound Meter Installation and Maintenance Guide Notes...
Страница 44: ...Appendix A 32 TRU FLO Compound Meter Installation and Maintenance Guide Notes...
Страница 57: ......