12: If an Intermittent Leak is Repaired
If an intermittent leak is found and repaired, complete
the following steps.
1. Check the sweep hand after at least 24 hours.
If the leak has been correctly repaired, the sweep
hand does not move.
2. Refer to the following table which describes the
standard functions of the ProCoder™ flags.
(When connected to an R900
®
MIU)
Backflow Flag (Resets After 35 Days)
Based on reverse movement of the eighth digit, the
eighth digit is variable based on the meter size.
No backflow event
Eighth digit reversed less than
one digit
Minor backflow
event
Eighth digit reversed more
than one digit up to 100
times the eighth digit
Major backflow
event
Eighth digit reversed greater
than 100 times the eighth
digit
Leak Status Flag
Based on total amount of 15-minute periods
recorded in the previous 24-hour period.
No leak
Eighth digit incremented less
than 50 of the 96 15-minute
intervals
Table 6: ProCoder™ Flags