Troubleshooting the Solar Panel's Battery
You can measure both the batteries voltage open circuit (Voc)
and voltage under charge (Vuc). The Vuc is a simple method to
measure voltage without disabling the load or disabling the
system from charging. Use Voc when the battery end-of-life is in
question and a more accurate means of measurement is required.
Batteries should be tested for end-of-life whenever a particular
system begins to fall in a SOC below 80% repeatedly, or the
system begins to exhibit LVD on a recurring basis. Battery life
varies depending on load use, depth of discharge, and temperature
extremes, but can vary between three to ten years.
To measure for battery end-of-life, complete the following steps.
1. Disconnect the battery from the system.
2. Charge the battery with an appropriate three-stage battery
charger.
3. After completion, allow the battery to settle for three hours
with no charge or load attached.
Table 25 provides Voc and Vuc for SOC at 25°C.
SOC (%)
Voc
Vuc
100
12.8
14.2
80
12.6
12.91
60
12.3
12.60
40
12.0
12.25
20
11.8
11.81
0
<11.6
<11.81
Table 25 – Voltages for SOC at 25°C
R900 Gateway Installation and Maintenance Guide
93
Appendix A Solar Power Information
Содержание 13458-000
Страница 2: ......
Страница 3: ...R900 Gateway v4 Installation and Maintenance Guide...
Страница 6: ...This page intentionally left blank...
Страница 26: ...This page intentionally left blank Chapter 1 Overview 8 R900 Gateway Installation and Maintenance Guide...
Страница 116: ...This page intentionally left blank Appendix A Solar Power Information 98 R900 Gateway Installation and Maintenance Guide...
Страница 149: ......