Apex PAR Monitoring Kit (PMK) - Setup Guide 

Page 4 

Once connected, you must tell the ASM that a PAR sensor is connected.  You will only need 
to do this once.  You may do this using the display menu or through the Apex dashboard.  
This cannot be done through APEX Fusion. 
 
If using the display menu: Go to Setup –> Module Setup –> Config Module –> ASM_# - 
Set Probe Type
.  ‘Par’ will usually be preselected; if it is not, use the up or down buttons to 
scroll until ‘Par’ is shown.  Press the center button, then press the Home button.    
 
If using the Apex dashboard: Navigate to Configuration -> Module Setup, and select the 
ASM.  In the ASM Configuration block, use Probe Type dropdown to select ‘Par’ if it not 
already selected.  Then click the Update button.  Do not change the default values for 
Range Minimum and Range Maximum. 
You will begin seeing PAR readings within a few seconds.  Note that graph data will appear 
on your dashboard once data is accumulated.  Based on your logging interval and system 
performance, this may take a few minutes to an hour. 
 
You can rename your probe from the default Parx_Y where ‘Y’ is the module number 
assigned by the controller to your ASM module.  For our examples, we’ll assume we’ve 
renamed it to ‘PAR’.  You can do this using either your Display module (Setup –> Module 
Setup –> Modify Name)
 or using the native dashboard by navigating to the Configuration – 
Probe/Input
 web page.  Note that you cannot rename probes in Fusion at this time. 
 

VERIFY THE INSTALLATION 

After your ASM is connected to your Aquabus and the PAR probe attached, you can verify 
your installation either with your Display module (navigate to Setup – Module Setup – 
Modify Name
 to see it listed) or via the classic Dashboard via the Configuration – Module 
Setup
 web page. 
 
You can add your PAR probe to your dashboards (native and/or Fusion) by dragging it from 
the unused tiles bin to the active dashboard.  With the native dashboard you click on the 
EDIT button, drag then save.  In Fusion you click on the padlock icon, drag then click on 
the padlock icon a second time to lock.  You can find more detailed instructions at Neptune 
Systems Support web page. 

 

PROGRAMMING EXAMPLES 

The PAR probe values may be used in outlet programming just like your other probes such 
as Temp, pH, ORP or Conductivity.  All of the program statements that work for those 
probes will work for your PAR probe.  For example, if you want an email alert whenever 