The switching tube is kinked or jammed.
The PN-hose in the control box is unfaste-
ned.
The PG gland of the installation kit is tighte-
ned too much. (The PN hose is pinched) /
The PN hose goes off from the push button.
The push button is
broken
Check whether the pump can be switched from the
control box.
Fix on the PN hose again.
Remove the PG gland a little bit. / Check that there
is no water in the push button and fix it on again
with the clamping sleeve. Call a pool specialist
company.
error / cause / repairing
The pump is very loud and does not bring the normal power.
Wrong motor direction of rotation
Reverse the polarity of motor by swapping the phase
(400 V).
The pump is loud and does not take full power.
The engine cover swipes.
Fan cover loosely, fix properly.
The pump is not running or is running difficultly and slowly.
A phase is missing.
Change supply line.
When turning on, the fuses switch.
incorrect fuses
Use fuse 16A inert.
The motor protection is triggered.
incorrect setting
Set the correct current value + 10%.
The pump can not be switched from the pool.