GB
- 15 -
When installing, never hang the equipment by
the discharge line or by the power cable. The
equipment must be hung up by the provided carry
handle or suspension eyelet, or it must rest on the
bottom of the shaft. To ensure that the equipment
works properly, the bottom of the shaft always
must be free of sludge and other accumulations
of dirt. If the water level is too low, the sludge
in the shaft can quickly dry out and hinder the
equipment from starting. It is necessary therefore
to check the equipment regularly (carry out trial
start-ups).
The pump shaft should be large enough.
5.2 Mains connection
Danger!
The equipment you have purchased comes with
an earthing-pin plug. The equipment is designed
for connection to a socket outlet with earthing
contact for 230 V ~ 50 Hz. Make sure that the
socket-outlet is su
ffi
ciently fused (at least 6 A)
and in good working order. Insert the power plug
in the socket-outlet and the equipment is ready
for operation.
6. Operation
You can put the equipment into operation after
you have thoroughly read the installation and ope-
rating instructions. Pay attention to the following
points:
•
Make sure that the equipment is set up secu-
rely.
•
Check that the discharge line is fitted correct-
ly.
•
Make sure that the electrical connection is
230 V ~ 50 Hz.
•
Check that the electrical socket-outlet is in
good working order.
•
Make sure that no moisture or water can ever
reach the power connection.
•
Make sure that the equipment does not run
dry.
•
To switch off the equipment, pull the power
plug out of the socket outlet.
Setting the On/O
ff
switching point:
The ON/OFF switching point of the
fl
oating switch
can be adjusted by shifting the
fl
oating switch in
the
fl
oating switch notched holder (Fig. 1/Item 5).
For this purpose you must
fi
rst slacken the screw
(Fig. 1, Item 6).
•
The floating switch must be fitted so that the
switching point height: ON and the switch
point height: OFF can be reached easily and
with little force. Check this by placing the
equipment in a container filled with water
and carefully raising and lowering the floating
switch with your hand. You can then see whe-
ther the equipment switches on and off.
•
Make sure that the distance between the floa-
ting switch head and the cable holder is not
too smaller than 10 cm. If the distance is too
small, there is no guarantee that the equip-
ment will work correctly.
•
When adjusting the floating switch, make
sure that the floating switch does not touch
the bottom before the equipment is switched
off. Important! Risk of dry running.
Manual operation:
Mount the
fl
oating switch as illustrated in Fig. 1.
The equipment will then run continuously. To pre-
vent dry running, this operating mode is allowed
only under supervision. The equipment must be
switched o
ff
(pull out the power plug) as soon as
no more water is emitted from the discharge line.
Dirty water mode (Fig. 3/4):
•
Turn the equipment counter-clockwise up as
far as the stop.
Shallow suction mode (Fig. 3/4):
•
Turn the equipment clockwise down as far as
the stop.
•
In shallow suction mode, water can be su-
cked up down to a level of 1 mm.
•
Only clean water can be sucked up in shallow
suction mode.
Please note:
For the equipment to suck up water in shallow
suction mode there must be a minimum depth of
10 mm of water.
Anl_NKSP-E_52_2in1_SPK7.indb 15
Anl_NKSP-E_52_2in1_SPK7.indb 15
28.01.2021 08:38:46
28.01.2021 08:38:46