Step 2 – Connect the Wiring Harnesses   

Each  BDM-600  comes  with  an  integrated  trunk  cable  to  simplify  the  AC 

connec

on process.  The  AC  trunk cable  includes  a male connector on one end 

and a female connector at the other end. Plug the male AC connector of the 

rst 

BDM-600 into the connector on the tail cable. Plug the female AC connector of 

the 

rst  BDM-600  into  the  male  connector  of  the  next  BDM-600  (or  jumper 

cable) and con

nue this “daisy chain” process  to form a con

nuous AC branch 

circuit.

 

Terminate  the 

nal  female  connector  on  the  last  microinverter  in  the 

branch circuit with the protec

ve cap. The connectors are keyed with a snap lock 

pin. A “click” indicates proper ma

ng. Secure the mated connector pairs and any 

excess AC cable to the rail or racking using cable clips or wire 

es   

 

WARNING: 

DO  NOT  EXCEED  THE  MAXIMUM  NUMBER  OF  SEVEN  (7)  BDM-600s  IN  A 

240V  AC  BRANCH  CIRCUIT  (SIX(6)  FOR  208V)  AND  EACH  BDM-600  AC  BRANCH  CIRCUIT 

MUST BE SOURCED FROM A 20A MAXIMUM BREAKER.

 

Install a protec

ve end cap on the open female AC connector on the last 

microinverter at the end of the truck cable.     

WARNING: 

MAKE SURE PROTECTIVE END CAPS HAVE BEEN INSTALLED ON ALL UNUSED 

AC CONNECTORS. UNUSED AC BDM-600 WIRE HARNESS CONNECTORS ARE LIVE WHEN 

THE SYSTEM IS ENERGIZED BY T

 

 

The AC branch circuit should look as pictured below:

 

 

6.2 Installa

on Steps

 

WARNING:

 

CONNECT BDM-600S TO THE ELECTRICAL UTILITY GRID ONLY AFTER RECEIVING 

PRIOR APPROVAL FROM THE UTILITY COMPANYAND LOCAL AHJ.

   

WARNING:

 

BE AWARE THAT ONLY QUALIFIED PERSONNEL CAN CONNECT BDM-600 TO 

THE ELECTRICAL UTILITY GRID.   

Step 1 – System Layout 

Mark the approximate loca

on of each pair of PV modules on the racking system. 

Place the microinverters at the loca

on called out in the layout map and 

loosely

 

a�ach

  to  the  rails  using  the  MLPE  clamps.  Check  the  reach  of  all  DC  and  AC 

cabling. DC jumpers may be required for some modules. Reposi

on as needed.

   

WARNING:

 

ALLOW  A  MINIMUM  OF  2.75  INCHES  BOTH  BETWEEN  THE  TOP  OF  THE 

ROOF AND THE BOTTOM OF THE BDM-600 AND BETWEEN THE BACK OF THE PV MODULE 

AND THE TOP OF THE BDM-600. DO NOT PLACE THE BDM-600 IN A LOCATION SUBJECT TO 

DIRECT SUNLIGHT. 

 

 

1.

 

 

2.

 

 

3.

 

 

4.

 

 

5.

 

 
 
For ground mount, ballasted, or 

at roof deployments it may be necessary to 

a�ach 

the microinverters to the racking frame. 

 
 
 
 
 
 
 
 
Once the

 fi

nal posi

on is con

rmed, secure the microinverters using the MLPE 

clamps and torque per the manufacturer’s speci

fica�

ons. Typical values are about 

12 �

lbs (16.3 NM).   

 
 
 
 
 

07

06 

JUMPER

“Optional, to connect

separate array”

Содержание BDM-600

Страница 1: ...433 3252 FAX 81 092 433 3171 China Address No 1 Anhe Rd Tsingtao Export Processing Zone Tsingtao China 266113 TEL 86 532 87963900 FAX 86 532 81100917 Email info northernep com Web h p www northernep com h p www nep japan com h p www micro inverter jp Rev 2017 01 12 North American Version Dual Module Microinverter BDM 600 Installa on and Opera on Manual ...

Страница 2: ...Shipping Informa on 05 6 INSTALLATION 05 6 1 Pre installa on 05 6 2 Installa on Steps 06 Step 1 System Layout 06 Step 2 Connect the Wiring Harnesses 07 Step 3 Install the AC Branch Circuit Junc on Box 08 Step 4 Ground the System 08 Step 5 Complete the Connec on Map 09 Step 6 Connect the PV Modules 09 Step 7 Install the BDG 256 Monitoring Gateway 09 7 COMMISSIONING 10 8 OPERATING INSTRUCTIONS 10 9 ...

Страница 3: ...ds of power electronics automa c control signal processing and communica ons each holding mul ple U S and world patents in their specialty areas NEP has a complete product line of grid ed solar inverters including 180W 600W micro inverters 1 5kW 5kW single phase solar inverters 10kW 500kW three phase solar inverters and rapid shutdown devices Field deployment results demonstrated high system efficie...

Страница 4: ...THIS MANUAL IS NOT COVERED BY THE WARRANTEE INSTALLATIONS SHOULD BE DONE ONLY BY CERTIFIED ELECTRICIANS NOTHING INSIDE THE INVERTER SHOULD BE MODIFIED ONLY NEP APPROVED CABLING SHOULD BE USED TO CONNECT MICROINVERTERS ALL INSTALLATIONS SHOULD FOLLOW THE LOCAL ELECTRICAL CODES ADDITIONAL PROTECTION FOR THE AC WIRING FROM THE INVERTERS SHOULD BE PROVIDED AND MAY BE REQUIRED BY LOCAL AND NATIONAL WIR...

Страница 5: ...rail or frame a ach clamps 2 per microinverter AC junc on boxes mul ple op ons possible Cordgrip with locknut or strain relief fi ng one per branch circuit A subpanel may be required for systems with mul ple branch circuits Cable clips Sockets wrenches torque wrench mul meter small flat head screwdriver and mirror with extension rod Lightning and surge suppressor recommended 5 3 Lightning and Surge ...

Страница 6: ...NSTALLED ON ALL UNUSED AC CONNECTORS UNUSED AC BDM 600 WIRE HARNESS CONNECTORS ARE LIVE WHEN THE SYSTEM IS ENERGIZED BY T The AC branch circuit should look as pictured below 6 2 Installa on Steps WARNING CONNECT BDM 600S TO THE ELECTRICAL UTILITY GRID ONLY AFTER RECEIVING PRIOR APPROVAL FROM THE UTILITY COMPANYAND LOCAL AHJ WARNING BE AWARE THAT ONLY QUALIFIED PERSONNEL CAN CONNECT BDM 600 TO THE ...

Страница 7: ...ou create Step 6 Connect the PV Modules Connect all AC all system inter wiring connec ons prior to installing the PV modules 1 Mount the PV modules in the posi ons corresponding to their associated BDM 600 microinverter Each BDM 600 comes with two sets of oppositely sexed DC connectors 2 Connect the posi ve DC wire from the first PV module to the nega vely marked DC connector male pin on the BDM 60...

Страница 8: ...nica ng to the BDG 256 Green communica ng to the BDG 256 Status grounding fault The LED light is in solid red color In case of a fault the BDM 600 enters a protec ve mode and stops outputing power The fault message is usually sent to a connected BDG 256 gateway through the power line communica on The error message is then displayed on the screen of BDG 256 gateway by a 16 bit error code The table ...

Страница 9: ...talled to reduce the interference to PLC communica on If there are two or more separate BDM systems close by it is highly recommended to install LCF for each micro inverter system to block interference from adjacent other systems 7 If the problem persists please call customer support at NEP WARNING DO NOT ATTEMPT TO REPAIR THE BDM 600 IT CONTAINS NO USER SERVICEABLE PARTS IF TROUBLESHOOTING METHOD...

Страница 10: ...ower Grid Frequency Hz 59 3 60 5 Adjustable THD 3 at rated power Power Factor 0 99 at rated power SYSTEM EFFICIENCY CEC Efficiency 95 5 Night Time Tire Loss W 0 11 PROTECTION FUNCTIONS Over Under Voltage Protec on Yes Over Under Frequency Protec on Yes An Islanding Protec on Yes Over Current Protec on Yes Reverse DC Polarity Protec on Yes Overload Protec on Yes Ground Fault Detec on Integrated Prote...

Страница 11: ... NEP product specifica ons including high input voltage from generators and lightning strikes c the product if repairs have been done to it other than by NEP or its authorized service centers herea er ASCs d the product if it is used as a component part of a product expressly warranted by another manufacturer e the product if its original iden fica on trade mark serial number markings have been defa...

Страница 12: ...or Code s Brief Fault Descrip on and Photos monitoring gateway is required for verifica on Installa on Informa on Modules Used Modules Quan ty Inverters quan ty per string Installa on Company Name Installer Name For the informa on on our warranty terms and condi ons please see our website www northernep com en All fields must be completed in order to process claim Customer Signature Date All rights ...

Страница 13: ...12 0011 福岡市博多区博多駅前 3 10 24 藤井ビル 1F TEL 81 092 433 3252 FAX 81 092 433 3171 China Address No 1 Anhe Rd Tsingtao Export Processing Zone Tsingtao China 266113 TEL 86 532 87963900 FAX 86 532 81100917 Email info northernep com Web h p www northernep com h p www nep japan com h p www micro inverter jp ...

Отзывы: