background image

// NEOX

PacketRaven

QUICK USER GUIDE

Depending on the configuration of the TAP speed 

(see section 6.3)

 the LEDs light up in different combinations. 

It must be ensured that all devices connected to the NETWORK port are set to the same network speed when 

configuring the TAP speed. 

This is the only way to ensure smooth and transparent operation of the TAP. As soon as the TAP displays the 

desired or configured link speed via the LEDs, proper operation of the TAP is ensured.

4.1 Front View - Meaning of the LEDs

(C)

 RJ45 Network Port and Status LEDs 

(see section 4.1)

(D)

 2 Power LEDs for AC/DC 5V 

(see section 5.)

      It is possible to connect up to 2 power supply units to ensure power supply redundancy. 

(E)

 RJ45 Monitoring Port and Status LEDs 

(see section 4.1)

(F)

 DC Power LED for 12-48V DC 

(see section 5.)

      If power is supplied via the 12-48V DC connection, this LED lights up.

(G)

 Aggregation Mode LED 

(see section 6.2)

      If the Aggregation mode is activated instead of the standard Breakout mode, this LED lights up.

(A)

  Power over Ethernet (PoE+) LED

       If PoE voltage is fed in via the connected net

       work device, this LED lights up. 

(B)

 Link Loss Detection (LLD) LED 

(see section 4.1)

:

      LLD detects a non-existent link on one of its net

      work ports and then shuts down the other net   

      work port. 

      This state is indicated by the LLD LED lighting 

      up.

4. Front View - Ports and LEDs

For reasons of compatibility and EMC protection, our TAPS may only be operated with the supplied power 

supplies certified together with the TAP. If the TAP is nevertheless operated with power supplies other 

than those supplied, any warranty claim granted for the TAP will be voided!

(A)

  DIP switch for LLD on/off, TAP mode and speed

        (see section 6.) 

(B)

  Connection for 12-48V DC voltage.

       The polarity at the DC connection does not matter, as the TAP  

       automatically detects the live line and passes the power supply 

       to the TAP accordingly in the required form! 

(C)

  Redundant connections for AC/DC power supplies (5V)

5. Back View 

NETWORK and MONITOR Port 

=

 10M

NETWORK and MONITOR Port 

100M

NETWORK and MONITOR Port 

1G

Содержание PacketRaven PRP-SCC-1GA Series

Страница 1: ...tional SPAN ports on the other hand can distort the result because this tech nique works in store and forward mode and discards FCS CRC errors at the OSI layer 2 level instead of outputting them on the mirror port In contrast TAPs pass out these critical CRC errors without affecting the original data Furthermore a Copper Network TAP works like a diode and does not allow access to the network via t...

Страница 2: ...AP to a PoE port according to IEEE802 af please follow the installation steps below FirstconnecttheTAPtothePSE PowerSourcingEquipment deviceandmakesurethatthePoE LEDlightsup As soon as this lights up the PSE and the TAP have negotiated the power supply and you can now connect your PoE end device to the TAP This sequence must be followed so that the TAP can properly establish power supply via a PSE...

Страница 3: ...mode is activated instead of the standard Breakout mode this LED lights up A Power over Ethernet PoE LED If PoE voltage is fed in via the connected net work device this LED lights up B Link Loss Detection LLD LED see section 4 1 LLD detects a non existent link on one of its net work ports and then shuts down the other net work port This state is indicated by the LLD LED lighting up 4 Front View Po...

Страница 4: ...he TAP is configured for 100Base T then both monitoring ports will also com municate on 100Base T accordingly Switch value 00 Aggregation In this mode the data streams are bundled and output aggregated on both of the monitoring ports This allows you to evaluate the network data of a full duplex line simul taneously with a single network interface on your analyzer Due to the aggregation in hard war...

Страница 5: ...terchangeable plug head 5V Cable with ferrite ring 5V Connector Screwable hollow plug 5 5 mm outer diameter 2 1 mm inner diameter ITEM NO POWER SUPPLIES ACCESSORIES PRP PS EU Power supply unit with EU plug head PRP PS UK Power supply unit with UK plug head PRP PS US Power supply unit with US plug head PRP PS INT PSU with EU UK and US plug head PRP PS A Plug head EU UK or US PRP SCC 1GB PRP 1U3 PRP...

Страница 6: ...tSolutions PRODUCT OVERVIEW Portable Compact NETWORK FORENSICS Appliances High End NETWORK PACKET BROKER for up to 400G Modular Scalable NETWORK FORENSICS Solution Cost Efficient Next Gen NETWORK PACKET BROKER as Appliance or Virtual Modular Portable and Virtual NETWORK TAPS for up to 400G Advanced PACKET PROCESSING up to 400Gbps ...

Отзывы: