5 Utilisation with the control panel B-Control
5.1
Use of the control panel
5.1.1
Browsing in the menus
Press any key to turn on the backlight for the control panel screen.
Important
If no key is pressed within 3 minutes, the backlight will go out.
The key is used to access the various menus:
Tab.3
Menus available
Information menu
Chimney Sweep menu
Press the key to access the Information menu.
Press the key for 2 seconds to access the Chimney Sweep menu.
Keep pressing the key to scroll through the information.
Note
Thirty minutes after the key is pressed for the last time, the dis
play goes back to the main display.
5.2
Start-up
If the boiler was powered off:
1. Check that the heating system and the boiler are adequately primed
with water. Recommended pressure: 0.15 MPa (1.5 bar).
2. Check that the storage tank is filled with fuel.
3. Open the oil inlet valve.
4. Switch on the boiler.
A venting cycle is run automatically.
The display shows the operating status of the boiler, the heating flow tem
perature and any error codes.
5.3
Shutdown
5.3.1
Switching off the heating
1. Turn the setting button
all the way to the left until is dis
played.
Note
The frost protection function continues to run
Fig.15
MW-1000668-1
Fig.16
MW-1000667-1
2’’
Fig.17
MW-1000668-1
Fig.18
MW
-3
0
0
0
2
4
1
-2
5 Utilisation with the control panel B-Control
16
EFU FF
7641178 - v02 - 17102016