Tab.8
List of parameters in the
sub-menu of the User menu
Parameter
Description
CU-OH04 factory
setting
DP060
Number of timer programs selected for domestic hot water production mode
Can be set from 0 to 2
0
DP070
Domestic hot water temperature set point in comfort mode
Can be set from 40 to 65°C.
55°C
DP080
Domestic hot water temperature set point in reduced mode
Can be set from 10 to 60°C.
10°C
DP200
Domestic hot water production mode:
= timer programming
= manual mode
= frost protection mode
0
DP337
Water temperature set point in the domestic hot water tank in holiday mode
Can be set from 10 to 60°C.
10°C
Note
AP : Appliance Parameters = Appliance parameters
Tab.9
List of parameters in the
/
/ sub-menus of the User menu
Parameter
Description
CU-OH04 factory
setting
Factory setting
SCB-04B
SCB-04C
AP016
Central heating operation:
= off (no heating or cooling)
= on
1
not available
AP017
Domestic hot water tank operation:
= off
= on
1
not available
AP073
SUMMER / WINTER set point switch:
Can be set from 15 to 30°C
set to 30.5°C = function deactivated
22°C
only accessible
to the installer
AP074
SUMMER override:
= off
= on
0
0
AP082
Applying summer/winter time
:
= off
= on
1
not available
For more information, see
Browsing in the menus, page 19
8.1.2
COUNTERS /TIME PROG / CLOCK menus
Tab.10 List of sub-menus
Sub-menu
Description
COUNTERS
8 Control panel settings IniControl 2
7642066 - v03 - 26072017
EFU