For more information, see
Setting the timer program, page 30
6.3.3
Shutting down the installation
It is recommended that the boiler is kept powered on to ensure frost pro
tection.
6.4
Frost Protection
Caution
The frost protection function does not work if the boiler is powered
off.
Caution
The integrated protection system only protects the boiler, not the
heating installation
Caution
Have the boiler and heating system drained by a qualified profes
sional if the home is left empty for a long period of time and there
is a chance of frost.
Important
To prevent the radiators and the installation from freezing in pla
ces where that risk exists (e.g. in a garage or an equipment room),
we recommend the connection of an outside temperature sensor
to the boiler.
If the temperature of the water in the boiler falls too much, the integrated
protection device switches itself on. This device functions as follows:
If the water temperature is lower than 7°C, the circulation pump starts
up.
If the water temperature is lower than 4°C, the boiler starts up.
If the water temperature is higher than 10°C, the boiler shuts down and
the circulation pump continues to run for a short time.
6 Utilisation with the control panel IniControl 2
22
EFU C
7642053 - v03 - 17112016