NRU Series
61
Mode 3 ~ Mode 12
Mode 3 ~ Mode 12 have various power-on delay and power-off delay. Each
mode supports a hard-off timeout of 10 minutes.
Mode
Power-on Delay
Power-off Delay
Hard-off Timeout
3
10 seconds
10 seconds
10 minutes
4
10 seconds
1 minute
10 minutes
5
10 seconds
5 minutes
10 minutes
6
30 seconds
1 minute
10 minutes
7
30 seconds
5 minutes
10 minutes
8
30 seconds
10 minutes
10 minutes
9
3 minutes
1 minute
10 minutes
10
(A)
3 minutes
10 minutes
10 minutes
11
(B)
3 minutes
30 minutes
10 minutes
12
(C)
10 minutes
30 minutes
10 minutes
Mode 13 (D) / Mode 14 (E)
Mode 13 and Mode 14 are ignition power control modes with very long
power-off delay. Both modes support the feature of “smart off-delay”, which
automatically detect system status during power-off delay duration and cut
off system power if system is off in prior to power-off delay expired.
Mode
Power-on Delay
Power-off Delay
Hard-off Timeout
13
(D)
30 seconds
2 hours
10 minutes
14
(E)
3 minutes
2 hours
10 minutes
Mode 15 (F)
Mode 15 is reserved.
Содержание NRU Series
Страница 14: ...NRU Series 14 1 3 3 Rear Panel View 1 3 4 Bottom View ...
Страница 15: ...NRU Series 15 1 3 5 Anti vibration Mount Dimensions ...
Страница 42: ...NRU Series 42 5 Remove the two screws indicated on the rear panel 6 Remove the two screws indicated ...
Страница 43: ...NRU Series 43 7 Gently pull apart the enclosure ...
Страница 52: ...NRU Series 52 7 Secure the bottom panel with six screws four screws secure the four rubber stands ...