supplied through an external switching device, such as a
timer, or connected to a circuit that is regularly switched on
and off by the utility.
• The heater must not be located immediately below a
socket-outlet.
• Means for disconnection having a contact separation in all
poles must be incorporated in the fixed wiring in
accordance with the wiring rules.
• For correct installation on the wall, thanks to refer to
‘Installation on wall’ part.
• Fixed heaters are to be installed so that switches and other
controls cannot be touched by a person in the bath or
shower.
• Connect the two conductors and the pilot wire of the
supply cord to a connection box in respecting the following
polarities:
- Live: Brown
- Neutral: Blue
- Pilot wire: Black
• WARNING: The heater must not be used if the glass
panels are damaged.
• WARNING: In order to avoid overheating, do not cover the
heater.
Warning: this product shall be installed in the volume 2
only according the national wiring rules (For France NF C
15-100)
Note:
The above drawing is for reference only.
19