background image

Neomatica LLC”. Tag ADM34 ver..1.0 of 21.11.2022 

 

5 Tag firmware actualization

 

 

 

Wait until the sensor is detected  

To switch to the «Control» menu click the icon 

 

 

Click on «Firmware update»  

If the tag firmware version is less than the version of the current firmware available on the up-

date server, the message «Update available» will be displayed indicating the current version.  

To start the update process, click «update».  

To check the relevance of the firmware version and download it from the update server, the 

application needs Internet access. At the same time, traffic may be consumed or a fee for 

communication services may be charged by your mobile network operator. The «ADM-BLE 

Configurat

or» application does not support a continuous connection via the Internet. Syn-

chronization of firmware versions is performed no more than once a day. The sensor firm-

ware has a size of not more than 100 kB. 

 

6 Storage and Transportation

 

         
The tag should be stored in a warehouse at a temperature of 0C to +29

С and relative humidity at 

most 85 %.  

After transportation of the tag in sub-zero temperatures they should be stored at room temperature 

within 24 hours  

 

 
 

7 Warranty

 

 

The manufacturer guarantees the proper function of the tag within 12 months from the day of its 

sale if consumer meets all the requirements and follows all the rules of transportation, storage, in-

stallation and handling.  

The warranty does not cover:  

- tags with mechanical damages and defects (cracks and chips, dents, signs of impacts, etc.) 

caused by consumer as a result of handling, storage and transportation rules violation. When there 

are signs of oxidation or other proofs of liquid penetration in the sensor housing;  

- -tags with signs of electrical and/or other damages caused as a result of unacceptable changes in 

external power network parameters or improper use of the terminal;  

Содержание ADM34

Страница 1: ......

Страница 2: ...Neomatica LLC Tag ADM34 ver 1 0 of 21 11 2022 This operation manual refers to the Tag ADM34 Tag hereinafter the manual describes its functionality the procedure of its configuration and operation...

Страница 3: ...in ADM BLE Configurator 7 4 2 Main parameters of the tag 7 4 2 1 Mode of operation 8 4 2 2 Submode 9 4 2 3 Data package control 9 4 2 4 Other configurations 9 4 3 Configuration of broadcast in the mod...

Страница 4: ...th Low Energy 4 1 technology 2 Technical characteristics Operating temperature from 0 up to 40 Frequency range of radio interface 2400 2483 5 Hz Transmitter power up to 8 dBm Receiver sensitivity 96 d...

Страница 5: ...ou need the permission of the Geolocation or Location This is due to Google requirements for applications that provide data exchange with BLE devices since BLE technology includes positioning by BLE b...

Страница 6: ...only to permit the use of the Geolocation or Location but also to enable this function if it is disabled The tag will be found as soon as the next message is sent If the tag is not detected press bot...

Страница 7: ...Configurator in OS Android 4 1Configuration of the tag in ADM BLE Configurator To check or change the tag settings wait until it is detected and click on the icon to go to the menu Control If the tag...

Страница 8: ...s works as remote control for the ADM33 immobilizer It is possible to change the state of the immobilizer by buttons or by presence absence of signal Mixed device works as a tag and as remote control...

Страница 9: ...r each button Broadcast by button broadcasting starts after pressing the button and stops after the set time has passed Each button is set to the broadcast duration protocol and identifier Pressing th...

Страница 10: ...rn the battery power alert on or off Potencia del transmisor Setting transmitter power The lower the power the smaller the distance over which the signal will be transmitted Signal transmission range...

Страница 11: ...rformed by pressing one of the buttons The label transmits the identifier over the selected protocol with the set frequency after a short press on the button the corresponding identifier and protocol...

Страница 12: ...the continuous broadcast The tag transmits the identifier over the selected protocol at a set frequency Pressing a small button starts broadcasting pressing a large button stops broadcasting Chose th...

Страница 13: ...ied state at the specified frequency For example the immobilizer is set to switch relay to the off mode in the absence of commands and the tag is set to send a command to turn it on Immobilizer relay...

Страница 14: ...g begins after a short press on the button and stops after the set broadcast duration has expired Each button is assigned a state to which the immobilizer relay should switch In the Data package contr...

Страница 15: ...buttons are pressed Submode configuration isn t available in this case Configuration should be made in menu Data package control To get access to control the immobilizer ADM33 enter Immobilizer MAC ad...

Страница 16: ...re than once a day The sensor firm ware has a size of not more than 100 kB 6 Storage and Transportation The tag should be stored in a warehouse at a temperature of 0C to 29 and relative humidity at mo...

Страница 17: ...th multipack and individual package is possible 9 Disposal Disposal of the tag and discharged battery is performed according to national and local norms and requirements 10 Scope of supply Device name...