4
Turn the red power switch to the ON position and the machine starts.
♦
Transfer chain speed setting
Tap the speed parameter on the screen and press the Up/Down button to set the appropriate transfer
chain rotation speed. When the speed is set, the time required to transport a PCB at this setting
speed is displayed on the right side of the screen.
♦
Temperature zone setting
Tap the temperature parameter on the screen and press the up/down buttons to set the temperature.
Black is “the set temperature”, and orange is “the real-time temperature”.
♦
Save and Usage of speed and temperature settings
After setting the transfer chain speed and the temperature of each zone, you could press the SAVE
button to save the setting parameters of the transfer chain and the zone temperature. When the
SAVE button is pressed, it will enter the TAB interface. Click on a TAB, then you can use the
"<<<", ">>>" "Up" and "Down" buttons to change the TAB name, long press OK to save these
parameters to this TAB.
When you would like to call the previously saved speed and temperature of the transport chain,
click the LOAD button on the screen to enter the TAB interface, click the TAB name, and then click
the CONFIRM button to load the speed and temperature settings of the transport chain.
Speed setting
Time required
to transport a
PCB
Temperatur
e setting
Power switch