Hangzhou NeoDen Technology Co.,Ltd.
20
situation to change the whole stack place angle.
component footprint: through select some footprint information, during the vision
adjustment process, the data here is which directly refer to the data in the library
image adjustment: can choose flying adjustment, up-looking camera also cannot choose
adjustment, which confirm by yourself.
flying adjustment can based on demands to select recognition brightness, it may appear the
component cannot be recognized, we need to adjust the brightness to help recognize (in
generally, resistance and capacitance needn’t increase luminance)
background noise: Use it to eliminate noisy point when taking photos, as usual, adjust it to 1
or 2 will be fine
●
nozzle information setting
Figure (2.1.5.2-4)
Function: choose nozzles according to the situation of installation nozzles and components,
can choose single or multistep machine will automatically allocate them to corresponding stack
in order to satisfy single or multi nozzles working demands. Also, there is detecting function
inside: see figure (2.1.5.2-4)
the height downgoing test: after clicking the option, the nozzles will go down, check to
ensure whether the nozzle pick height is suitable, if it’s not suitable, reset the pick height in
stack information.
pick test: the single nozzle will pick a component when click corresponding picking test,
after finish this test, check the actual situation of picking components, if there are questions,
need to reset picking location in the basic stack information’s option
feed test: feeder feeding, which used to test the feeders work normal or not.
After finishing the above stack’s information setting, click the option to assign the component
type to the stack automatically, the components list will do corresponding variation, then click
save and back. In this way, the whole program is finished.
2.2 File Mounting
Method to mount one file, see figure (2.2):
Содержание 7