P. 13
- Neo Proton IP 7 QA
Connection of the DMX line
DMX connection employs standard XLR connectors.
Use shielded pair-twisted cables with 120Ω im
-
pedance and low capacity. The following diagram
shows the connection mode:
ATTENTION
The screened parts of the cable (sleeve) must never
be connected to the system
'
s earth, as this would
cause faulty fixture and controller operation.
Over long runs can be necessary to insert a DMX
level matching amplifier.
For those connections the use of balanced micro-
phone cable is not recommended because it cannot
transmit control DMX data reliably.
• Connect the controller DMX input to the DMX
output of the first unit.
• Connect the DMX output to the DMX input to
the following unit. Connect again the output to
the input of the following unit until all the units
are connected in chain.
• When the signal cable has to run longer dis-
tance is recommended to insert a DMX termina-
tion on the last unit.
Beam Angle: 38° (D45)
Proyect Distance (m)
1m
5641 lux
627 lux
226 lux
115 lux
56 lux
3m
5m
7m
10m
Luminance (lux)
Full
DMX-INPUT
XLR plug
Pin1: GND - Shield
Pin2: Negative
Pin3: Positive
Pin4: N/C
Pin5: N/C
DMX-OUTPUT
XLR socket
English version