background image

•  Please visit 

NeoLogicSolutions.com

 or call 

888.859.1188

 to order replacement parts.  

Our WQA Certified Water Specialist are always happy to help determine the best solutions.

•  

Stage 1 Replacement:

  

Part# TLR-A3502, Chloramines, Carbon Block with Lead, Cyst and Pharmaceutical Reduction

•  Stage 2 Replacement:

  

Part# TLR-A3502, Chloramines, Carbon Block with Lead, Cyst and Pharmaceutical Reduction

•  Stage 3 Replacement:

  

Part# TLR-A5HF12, Hollow Fiber Membrane

Your Home For Replacement Parts:

6

TL3-A502 system tested and certified by IAPMO R&T Lab and IAPMO R&T against NSF/ANSI Standard 42 for the  

aesthetic reduction of chlorine taste and odor, aesthetic chloramines, and particulate class I. NSF/ANSI Standard 53  

for the reduction of asbestos, cyst, lead, mercury, MTBE, turbidity, and VOC. NSF/ANSI Standard 401 for the reduction  

of Bisphenol A, Estrone, Ibuprofen, Naproxen, Nonyl phenol, and Phenytoin. Conforms to NSF Protocol P231 for the  

reduction of bacteria, virus, and cysts. 
System conforms to NSF/ANSI Standards 42, 53, 401, and NSF Protocol P231 for specific performance claims  

as verified and substantiated by test data. See Performance Data Sheet for reduction performance.
Compounds certified under NSF/ANSI Standard 401 have been deemed as incidental contaminants. 
This system is not intended to convert waste water or raw sewage into drinking water. 

EPA Establishment Number: 088572-CHN-001. All rights and illustrations reserved.  

Made in China. Manufacturer reserves the right to make changes without notice. ©2017 NeoLogic Solutions

2299 Ridge Rd., Greenville, SC 29607 

Call: 888.859.1188 • Email: [email protected] 

Visit: NeoLogicSolutions.com

Distributed By:

Содержание TL3-A502

Страница 1: ... Stop Valve Adapter ASVA C4 Faucet Connector C4 Insert C5 Ferrule C6 Compression Nut Package Contents Two Phillips screws at least 7 8 to 1 long Phillips Screwdriver 1 8 Drill Bit Center Punch Adjustable Wrench Utility Knife File Tape Measure Safety Glasses Masking Tape Newspaper or Towels Pencil Bucket or Pan Required Tools And Materials Plumber s Tape Hacksaw Optional Materials Drill with 1 4 9 ...

Страница 2: ...propriate seal of tubing in collet inlet outlet ports STEP 4 2 3 Mark the drill hole using a center punch 4 Make a pilot hole using the 1 4 drill bit Use the 9 16 or 5 8 drill bit to drill the final hole Drill through the sink or countertop completely and smooth rough edges with a file 5 Unscrew the faucet stem nut from the faucet stem and remove the metal lock washer Slip the threaded faucet stem...

Страница 3: ... Installation Instructions Prior to installing each TLR A3502 cartridge in its position we need to perform a flushing step in order for the filter system to flush out any air and carbon fines fine black powder from each cartridge To Install A Cartridge 1 Hold each cartridge with the front label facing a quarter turn to the left 2 Lift each cartridge straight up into the system head until the two n...

Страница 4: ... on the faucet for filtered water If there are leaks on the Angle Stop Valve Adapter connection To release pressure turn off the cold water shut off valve to the filter system Identify the Angle Stop Valve Adapter If the tubing is leaking follow If there are leaks around the fittings instructions above If the thread between the Angle Stop Valve Adapter and the kitchen faucet stem is leaking tighte...

Страница 5: ...or use of electrical equipment on these units Cartridges can last up to 12 months depending on water quality and usage Cartridges should be changed when water pressure decreases or chlorine odor intensifies OPERATION MAINTENANCE DATA 5 Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system Systems certified for cyst red...

Страница 6: ...sbestos cyst lead mercury MTBE turbidity and VOC NSF ANSI Standard 401 for the reduction of Bisphenol A Estrone Ibuprofen Naproxen Nonyl phenol and Phenytoin Conforms to NSF Protocol P231 for the reduction of bacteria virus and cysts System conforms to NSF ANSI Standards 42 53 401 and NSF Protocol P231 for specific performance claims as verified and substantiated by test data See Performance Data ...

Отзывы: