D. R.O. MANIFOLD ASSEMBLY INSTRUCTIONS 

 

Locate the site per Sec. III, C.3. Various installation sites will require different types of mounting fasteners; be sure the fastener 

selected will provide a firm, solid mounting. A support panel may be necessary on thin cabinet walls or to span between wall studs  

on particleboard or drywall. 

Do not drill through exterior cabinet walls or leave sharp wood screw points exposed in readily accessible cabinet interiors. 

The close proximity of a dishwasher or a trash compactor may require special fabrication of a mounting plate.

SECTION IV. INSTALLATION STEPS

16.  

The mounting bracket will accept either #10 or #12 

(5mm) mounting screws spaced on 6" (15 cm) centers. 

Allow at least 4" (10 cm) of clearance beneath the filter 

housings to accommodate filter changes. Mark the 

two locations (the bracket can be used as a template). 

Install the screws and tighten them until the heads are 

about 5/8" from the wall.

17.  

Locate the ¼" Orange Feed Water Tubing. Remove  

the red plug from the fitting labeled “In” on the manifold 

and insert the tubing. Reference the special supplement 

sheet in the carton for proper connection of all tubing 

and removal of plugs. Run the tubing along its course  

to the Feed Water Valve, trim to length. (Refer to Fig. 1.) 

 

18.  

Locate the ¼" Black Drain Tubing. Remove the black 

plug from the fitting labeled “Drain” on the manifold 

and insert the tubing. The end of the Black Drain 

Tubing that should be inserted into the “Drain” port 

will have a drain restrictor in it. Run the tubing along 

its course to the ¼" Hose Barb on the Dispensing 

Faucet, trim to length and connect by firmly pressing 

over the barb. Allow the tubing to relax, then press 

firmly again to insure proper seating.

19.  

Locate the ¼" White tubing. Remove the yellow plug  

from the fitting labeled "Out" on the manifold and  

insert the tubing.

20.  

Locate the 3/8" Blue Product Water Tubing.  

Firmly press one end into the tee and the other  

end into the faucet connector. (Refer to Fig. 3.)  

The fittings will grab the tubing and seal it in place. 

Make sure the tubing is pressed all the way in to  

create a pressure tight connection. 

 

NOTE: If you want to pull the tubing out for  

some reason, push the ring around the tubing  

in and pull the tubing out.

21.  

Hang the Manifold Assembly on the mounting screws  

and tighten. DO NOT OVER-TIGHTEN.

22.  

Remove the wrapping from the In–Line Activated 

Carbon Post-Filter. Slice the 3/8" Blue Polytube where 

it would be convenient to install and change the In–

Line Filter. Make a clean straight cut to insure proper 

connections. The “Out” port on the In–Line Filter should 

be toward the faucet. Firmly press in the tubing. The 

fittings will grab the tubing and seal it in place. Make 

sure the tubing is pressed all the way in to create a 

pressure tight connection. 

E.  POSITION THE DRINKING WATER  

HOLDING TANK AND MAKE THE FINAL  

HOSE CONNECTIONS.

1.  

Check the tank precharge pressure. Make sure it is 

between 5 to 7 psig. If not, use a bicycle hand pump  

or other pump to bring the pressure up to the 5 to 7  

psig range.

2.  

Wrap Teflon tape three times around the ¼" male  

outlet thread. Wrap in the direction of the threads 

(clockwise when looking down on the Holding Tank). 

The tape will act as a thread sealant. Screw on the 

Holding Tank Shut–Off Valve.

3.  

Locate the 3/8" White Tubing. Firmly press one  

end into the Holding Tank Shut–Off Valve and the  

other end into the tee. (Refer to Fig. 1.) The fittings  

will grab the tubing and seal it in place. Make sure  

the tubing is pressed all the way in to create a  

pressure tight connection.

12

Содержание RO-4300Rx

Страница 1: ...The High Efficiency Reverse Osmosis Drinking Water System Installation Operation And Service Manual DLX ...

Страница 2: ...MICROBIOLOGICALLY UNSAFE OR OF UNKNOWN QUALITY WITHOUT ADEQUATE DISINFECTION BEFORE OR AFTER THE SYSTEM Systems certified for cyst reduction may be used on disinfected water that may contain filterable cysts TABLE OF CONTENTS Section I Introduction 2 Section II Specifications 5 Section III Preparation 6 A Major System Components 6 B Tools Recommended For Installation 6 C Site Selection For Major S...

Страница 3: ...for substances that contribute to tastes and odors IN LINE ACTIVATED CARBON POST FILTER The In Line Activated Carbon Post Filter is located after the Holding Tank and has been designed to reduce the tastes and odors that may pass through the system It adds a final polish to the water AUTOMATIC SHUT OFF VALVE The ASO Valve senses when the Holding Tank is full and closes the feed water supply to pre...

Страница 4: ...uct 3 8 Blue 6 7 8 Polytube Tee Stage 3 Carbon Post Filter Housing Stage 2 Reverse Osmosis Membrane Housing Stage 1 Sediment Carbon Pre Filter Housing Locate Drain Clamp Above P Trap Feed Water Valve Cold Water Line Only Drinking Water Holding Tank Holding Tank Shut Off Valve Open Position Drain 3 8 Black Tank 3 8 White 9 11 Permeate Pump Connection Guide RO Water Permeate RO Water Out To Tank Dra...

Страница 5: ... this manual Cover RO Manifold Drinking Water Holding Tank Mount Holding Tank On Shelf Or Strap Between Floor Joists Shelf or straps not included Stage 3 Activated Carbon Post Filter Housing Stage 2 Reverse Osmosis Membrane Housing Stage 1 Sediment Carbon Pre Filter Housing Drain 1 4 Black Feed 1 4 Orange Blue Blue White 1 Air Gap Required Basement Floor PLEASE NOTE If Air Gap in faucet is not use...

Страница 6: ...able to the user as reverse osmosis treated water when the system is operated without a storage tank or when the storage tank is bypassed Efficiency rating means the percentage of the influent water to the system that is available to the user as reverse osmosis treated water under operating conditions that approximate typical daily usage This reverse osmosis system contains a replaceable component...

Страница 7: ...ews or machine screws and nuts for mounting the manifold or concrete anchors for hanging on basement wall Additional tubing or tube connectors Plastic wire ties for organizing tubing B TOOLS RECOMMENDED FOR INSTALLATION The following tools will cover most of the installation sites encountered Mounting Faucet 1 3 8 variable speed electric drill 2 1 porcelain hole cutter kit 3 1 Greenlee hole punch ...

Страница 8: ... as it will extend the life of the R O Membrane 3 R O Manifold Assembly The manifold can be installed on either the right or left side of the under sink area or a cabinet The right side is recommended because all the tubing will be to the back of the cabinet and out of the way Installation in the basement is also an option one location is near the laundry utility sink where cold potable water and ...

Страница 9: ...asher Rubber Connector Faucet 3 8 x 7 16 Drain Line From Air Gap To Drain 3 8 Black Tubing Drain Line To Air Gap 1 4 Black Tubing AIR GAP ONLY GRINDING WHEEL Sink Top Metal Porcelain CAUTION Be careful when the drill is about to penetrate the base metal of the sink Reduce the speed and support the drill so the drill chuck does not impact the porcelain or enamel FAUCET DIAGRAM FIGURE 3 ...

Страница 10: ...s Punch 5 Set the punch and turn the nut with a wrench to cut the hole D PREPARE THE R O AIR GAP FAUCET ASSEMBLY FOR INSTALLATION 1 Using the diagram in Figure 3 assemble the Air Gap Spigot with all the components except the slot washer Begin with the escutcheon followed by the rubber gasket spacer flat washer 9 16 nut and 3 8 spigot adapter 2 Using the diagram in Figure 2 from under the sink feed...

Страница 11: ...sion nut on the feed water supply valve Do not over tighten 10 Reconnect the riser tube to the other end of the feed water supply valve Do not over tighten 11 Fully insert the red 1 4 tube into the speed fit connection and replace the red locking clip The new feed water valve can be swiveled to position the tubing out of the way of under sink items 12 Make sure the feed water supply valve is off b...

Страница 12: ...g Faucet Route the tubing to the Drain Clamp and trim to length NOTE When cutting the polytubing make clean square cuts failing to do so could result in poor connections and possible leaks CAUTION The lowest point of the line should be the point of connection to the Drain Clamp There should be no sag in the line as this may cause excessive noise as the reject water is flowing to drain Insert the t...

Страница 13: ...then press firmly again to insure proper seating 19 Locate the White tubing Remove the yellow plug from the fitting labeled Out on the manifold and insert the tubing 20 Locate the 3 8 Blue Product Water Tubing Firmly press one end into the tee and the other end into the faucet connector Refer to Fig 3 The fittings will grab the tubing and seal it in place Make sure the tubing is pressed all the wa...

Страница 14: ...LOSE the Feed Water Valve and open the Dispensing Faucet Allow the Holding Tank to completely drain then remove the Sediment Carbon Filter Housing the farthest of the three from the In Out ports empty and install the Sediment Carbon Pre Filter Firmly tighten the Housing hand tight only Remove the Activated Carbon Filter Housing the closest of the three to the In Out ports empty and install the Act...

Страница 15: ...tion it is better to empty the Holding Tank and allow the system to produce fresh water for use If the system is not used for 3 4 weeks or longer it is a good idea to re sanitize the system and to change the Pre Filter and Post Filters B CHANGING FILTERS THIS R O SYSTEM CONTAINS FILTERS WHICH MUST BE REPLACED AT REGULAR INTERVALS TO MAINTAIN PROPER PERFORMANCE USE ONLY FACTORY APPROVED FILTERS All...

Страница 16: ...f the Faucet in the following order close the Faucet and open the Holding Tank Valve When the Faucet is first opened expect air and carbon fines very fine black powder from the new Post Filter to be rinsed out This is normal for the first tank of watertight connection 7 The RO 4300RX Deluxe System includes upgraded quick release fittings which help make change outs easier Thread male inserts B and...

Страница 17: ...stem A The Permeate pump brine side should be installed between the R O System and the air gap faucet connection From the R O plug black tube into BRINE IN port B Connect a new length long enough to reach the air gap drain of tubing to the BRINE OUT fitting on the Permeate Pump Be sure tube bottoms out in the fitting This tube connects directly to the air gap drain 6 Locate the product water perme...

Страница 18: ... ASO Valve is malfunctioning In Line Activated Carbon Post Filter is plugged LOW PRESSURE AT THE DISPENSING FAUCET In Line Activated Carbon Post Filter is plugged Replace Post Filter Air precharge in the Holding Tank is too low Empty water from Holding Tank and with the faucet open adjust the air pressure to 5 7 psig 35 48 kPa range Check for leakage at the Air Valve Stem Holding Tank Valve is par...

Страница 19: ... gases in the Feed Water Pretreat Feed Water to remove dissolved gases Increase in Product Water TDS See high TDS in the Product Water section AMBER LIGHT ON WATER QUALITY MONITOR System not being used for extended period of time Empty storage tank Wait 15 minutes for the system to begin making water and test water quality again Filters are plugged or membrane is fouled or exhausted Replace filter...

Страница 20: ...EXPLODED VIEW AND PARTS LIST 19A Water Quality Test Kit 23 Nitrate Nitrite Test Kit Optional Deluxe Components 17 19 20 14 13 12 11 16 18 10 9 15 1 2 3 4 5 6 7 8 24 25 19 ...

Страница 21: ...R O Membrane 50 gpd 189 lpd Part No CLK TF 50 13 Housing O Ring 14 Housing 15 Water Quality Monitor Board w Probes 16 Drain Restrictor 50 GPD 189 lpd Green 17 Cover 18 Activated Carbon Post Filter Part No CML CB 19 Water Quality Monitor Indicator and Cord 20 Wrench for Housing 21 1 4 3 8 Fitting Wrench 22 In Line Activated Carbon Post Filter 23 Nitrate Nitrite Test Kit 24 Alkamag Alkaline Inline W...

Страница 22: ...nt and carbon filters whose service life depends on feed water conditions In addition the membrane is only warranted if the required feed water conditions are met The above warranty will also not apply to any part of the Neo Pure R O Drinking Water System that is damaged because of neglect misuse alterations accident misapplication physical damage or damage caused by fire acts of God freezing or h...