background image

 

sequence Setting)

  sequence Setting)

 

AP01-AP04 

(Mode Selection)

AP04-AP01 

(Mode Selection) 

Auto Mode 

AP** 

S.000-S.008 

(Strobe Speed) 

S.008-S.000 

(Strobe Speed) 

r.000-r.008 

(Red) 

r.008-r.000 

(Red) 

g.000-g.008 

(Green) 

g.008-g.000 

(Green) 

b.000-b.008 

(Blue) 

b.008-b.000 

(Blue) 

u.000-u.008 

(White) 

u.008-u.000 

(White) 

Manual 

Mode 

coLo 

F.000-F.008 

(Strobe Speed) 

F.008-F.000 

(Strobe Speed) 

Sound Mode 

Soun 

SP.01-SP.02 

(Sound Mode) 

SP.02-SP.01 

 (Sound Mode) 

4 Channel 

Control 

Mode 

4-CH 

Key Press doesn’t work in this mode 

3.Function Instruction: 

3-1、DMX Mode:when the fixture works as a single unit, please set Par.0 in the DMX working mode. When CH1=255、

CH5=1、CH6=2、CH7=3,CH8=4,it will switch to Obey4 control mode directly. When the fixtures works as a set, please 
set Par. 1~4 and DMX address A001. If the fixture is set to Par.0 or other DMX address, the slave units will 
work out of the way. 

3-2、Auto Mode: There are 4 modes, which is AP01-AP04. Strobe speed can be set in each mode.  

3-3、Manual Mode: Under this mode, RGB brightness and strobe speed can be set manually. r.000-r.008 refers 

to the brightness of red color、g.000-g.008 refers to the brightness of green color、b.000-b.008 refers to the 
brightness of blue color、u.000-u.008 refers to the brightness of white color. Strobe speed setting is the same 
as 3-2.  

3-4、Sound Mode: Adjust the sound sensitive to the most suitable place and inset two kinds of sound modes 

3-5、Temperature Protection Mode: Press Menu Button and then Enter Button, it will show the temperature 

of the light panel.  

4.Single Par Light Usage and DMX Channel Instruction: 

4-1、DMX Controller Connection: 

 

 

 

1

                                   

n

 

 

 

 

 

4-2、DMX Channel Instruction: 

DMX 

Channel 

Function  

DMX512 Value

Description 

000~030 

DMX Mode(CH2、CH3、CH4、CH5、CH6,CH7) 

031~080 

Color Shade ,

( CH2,CH3、CH4、CH5、CH6,CH7) 

081~140 

Color Auto Mix(CH3) 

141~170 

RGBW Auto Switch(CH3) 

171~200 

15 colors Auto Switch(CH3) 

201~240 

Color Shade Automatically(CH3) 

CH1 

Mode 

241

255

241~245:Sound Mode 1 

Dmx line 

DMX512 Controller / 

4- Channel Controller 

Fixture

Signal

 

Par Par.0

AC Power 

100~240VAC 

50/60Hz 

Fixture

Signal

 

Par Par.0

Power line

2/ 7 

Содержание IRDIP-9007456-01D-13

Страница 1: ...ys long life span It can work in DMX Manual Auto Sound and Linkable modes It is also user friendly which makes it suitable for all kinds of entertainment and decorative industries The fixture can be used as a single unit or a PAR Light Set 4 PCS or 4 N PCS Packing Listing 1 IRDIP 9007456 01D 13 7x10W 4IN1 Indoor Par Light One 2 User Manual One 3 Power Cable One 4 DMX Cable One 1 7 ...

Страница 2: ...r charge PAR Light Setting 1 Five Working Modes 1 Auto Run the internal program automatically 2 Manual Run the program manually 3 Sound Run the internal program by sound 4 DMX512 DMX control Mode 5 4 Channels Mode Run under the control by 4 Channels controller 2 Key Pressing and Digital Tube Setting 2 1 Operation Panel as Picture 2 shows MENU UP DOWN ENTER Picture 3 Picture 2 2 2 Instruction on Di...

Страница 3: ...each mode 3 3 Manual Mode Under this mode RGB brightness and strobe speed can be set manually r 000 r 008 refers to the brightness of red color g 000 g 008 refers to the brightness of green color b 000 b 008 refers to the brightness of blue color u 000 u 008 refers to the brightness of white color Strobe speed setting is the same as 3 2 3 4 Sound Mode Adjust the sound sensitive to the most suitabl...

Страница 4: ...djustment 0 100 CH6 Blue Brightness Adjustment 000 255 Blue Brightness Adjustment 0 100 CH7 White Brightness Adjustment 000 255 White Brightness Adjustment 0 100 四 Instruction on Par Light Set 5 1 Controlled By DMX Controller 5 1 1 Connection AC Power 100 240VAC 50 60Hz DMX512 Controller 4 Channel Controller 5 1 2 Channel Listing Light 1st Par Par 1 Dmx line Light 2nd Par Par 2 Dmx line Power line...

Страница 5: ...lection 016 255 Strobe Speed Selection CH4 Red LED Brightness Adjustment 000 255 Par 1 Red LED Brightness 0 100 CH5 Green LED Brightness Adjustment 000 255 Par 1 Green LED Brightness 0 100 CH6 Blue LED Brightness Adjustment 000 255 Par 1 Blue LED Brightness 0 100 CH7 White LED Brightness Adjustment 000 255 Par 1WhiteLED Brightness 0 100 CH8 Red LED Brightness Adjustment 000 255 Par 2 Red LED Brigh...

Страница 6: ...iece master unit or DMX controller 4 channel controller is connected the slave units may work out of the way 3 Master and Slave Working Mode for Par Light Set 1 Working Mode Setting Set up the DMX address A001 on all the Slave units and Par Light Sequence Par 1 4 Four pieces Par lights can form one set Or the fixture can link with other products Neo Neon produces so as to get more abundant stage e...

Страница 7: ... input voltage 1 Make sure that the input voltage is the same as the rating voltage The unit is not controlled by the DMX 1 Check the polarity of the DMX control signal 2 See whether the unit is working under DMX mode 3 Check whether there are two masters 1 Correct the polarity of the DMX signal 2 Set up DMX working mode 3 Select only one master in the loop Light set don t work rightly 1 Check the...

Отзывы: