background image

FIXTURE ANCHORING

Page 6 of 16

Part #: 6216-014-000

Date: 03/07/19

INSTALLATION, OPERATIONS 

& MAINTENANCE MANUAL

 NEO-METRO FIELD SERVICE

TOLL FREE

 800-743-8259 • 

LOCAL

  626-855-4866 • 

FAX

 626-855-4863

Please visit 

 

for most current specifications.

www.neo-metro.com

Locate and mount the mounting bracket to a finished wall. Locate and install P-Trap 

1

enclosure anchors provide by others.

NOTE: It may be advantageous to install to the deck, faucets, 
soap dispensers or other accessories prior to wall mounting. 

Hang deck and P-Trap enclosure onto mounting bracket , level 

3

and mount to the finished wall using 1/2” mounting hardware  

 

supplied by others.

Assemble deck to P-Trap enclosure using the 1/4”-20 hardware 

2

provided. (6 places)

 

1/4"-20 UNC X 1/2" HEX

HEAD CAP SCREW

(PROVIDED)

1/4" MOUNTING BOLTS

(PROVIDED BY OTHERS)

When P-Trap enclosure is in the 

4

closed position, secure P-Trap 

 

enclosure by securing cover catch 

 

to bottom of counter deck. 

Содержание SLAB-EDGE 9152

Страница 1: ... WASH BASIN MODEL 9152 SLAB EDGE Chalk Line Hammer Plumbers Putty 7 16 Hex Wrench 1 2 NPS Supply Angle Stops Carpenters Level Teflon Tape 9 32 Fixture Wall Anchors and Anchoring Hardware and Appropriate Tools 9 16 Fixture Wall Anchors and Anchoring Hardware and Appropriate Tools Part 6216 014 000 Page 1 of 16 Please visit www neo metro com for most current specifications INSTALLATION OPERATIONS MA...

Страница 2: ...ough ins before beginning any work File this manual with the owner or maintenance personnel upon completion of installation Industry standard wall backing for wall hung fixtures is required Installer provided wall anchors and wall anchoring hardware must be appropriate for wall construction and have a minimum pull out rating of 1000 lbs 453 6 kg ANSI UFAS or ADA compliance is subject to the interp...

Страница 3: ...IM MAX 27 17 9 22 33 4 17 9 OBC PROFILE 33 RIM MAX 22 33 4 34 RIM MAX 17 9 BCBC British Colombia Building Code ADA ages 6 thru 12 Part 6216 014 000 03 07 19 INSTALLATION OPERATIONS MAINTENANCE MANUAL NEO METRO FIELD SERVICE TOLL FREE 800 743 8259 LOCAL 626 855 4866 FAX 626 855 4863 Please visit for most current specifications www neo metro com ...

Страница 4: ...Part 6216 014 000 Date 03 07 19 INSTALLATION OPERATIONS MAINTENANCE MANUAL NEO METRO FIELD SERVICE TOLL FREE 800 743 8259 LOCAL 626 855 4866 FAX 626 855 4863 Please visit for most current specifications www neo metro com 56 22 17 24 ...

Страница 5: ...Electrical Receptacle when SO and SOS options are selected F Wall Anchoring Ø9 16 x 1 Long Angle Bracket Mounting Slots 8 Places G Wall Anchoring Ø9 32 x 3 4 Long Enclosure Mounting Slots 13 Places I Wall Anchoring Ø3 8 x 3 4 Long Trap Cover Mounting Slots 2 Places H Wall Anchoring Ø9 16 Mounting Hole Support Bracket Mounting 2 Places 31 787 ADA 6 13 34 864 ADA ADULT 34 864 BCBC 33 838 OBC 21 2 64...

Страница 6: ...ovide by others NOTE It may be advantageous to install to the deck faucets soap dispensers or other accessories prior to wall mounting Hang deck and P Trap enclosure onto mounting bracket level 3and mount to the finished wall using 1 2 mounting hardware supplied by others Assemble deck to P Trap enclosure using the 1 4 20 hardware 2provided 6 places 1 4 20 UNC X 1 2 HEX HEAD CAP SCREW PROVIDED 1 4...

Страница 7: ...eflon tape on all 5threaded connections and make up waste connections to 1 1 2 P Trap HINT Teflon tape is recommended on all threaded waste and supply connections Page 7 of 16 NOTE ADD TEFLON TAPE TO ITEM 1 BEFORE ASSEMBLING ITEM 5 1 2 3 4 5 71 2 Part 6216 014 000 Date 03 07 19 INSTALLATION OPERATIONS MAINTENANCE MANUAL NEO METRO FIELD SERVICE TOLL FREE 800 743 8259 LOCAL 626 855 4866 FAX 626 855 ...

Страница 8: ...stop leaks before proceeding 1 Loosen locknut 2 Turn on fixture and run water for at least 2 minutes Allow supply temperature to stabilize 3 Turn temperature stem counter clockwise for hotter or clockwise for colder outlet temperature 4 Tighten locknut to prevent accidental or unauthorized temperature adjustment 5 Re check outlet temperature Temperature Adjustment Valve Assembly Installation VALVE...

Страница 9: ...soap reservoir with provided hose clamps C Install soap dispenser s onto deck NOTE Gasket and Washer are located beneath the deck D Attach 3 8 O D Tubing to the dispenser s and reservoir NOTE Check Valve must be field spliced into tubing and installed with respect to direction of flow E HINT For best results install soap reservoir fill hole directly below soap filler on deck with refill tube as sh...

Страница 10: ...INISHED LAYOUTS SHOWN FOR REFERENCE Part 6216 014 000 Date 03 07 19 INSTALLATION OPERATIONS MAINTENANCE MANUAL NEO METRO FIELD SERVICE TOLL FREE 800 743 8259 LOCAL 626 855 4866 FAX 626 855 4863 Please visit for most current specifications www neo metro com ...

Страница 11: ...ion or pressurized air Debris or scale in diaphragm Remove diaphragm and clean Sensor flashes once when user s hands are within range Remove strainer and clean CONDITION FALSE TRIGGERING WATER FLOWS CONTINUOUSLY Indicators Probable Cause Solution Remove diaphragm and clean Sensor flashes when user s hands are within range Diaphragm is defective or torn Sensor is dirty or covered Clean or uncover s...

Страница 12: ...aighten valve riser tubing Debris or scale in checkstop strainer Remove checkstop strainer and clean Blockage in valve flow control Remove blockage Low water pressure at supplies Increase water pressure to 30 PSI minimum Lime deposits in hot water pipes CONDITION REDUCED WATER FLOW Probable Cause Solution Air leaks from 1 8 O D tubing or fittings Replace damaged tubing or fitting Pushbutton air di...

Страница 13: ...e indefinitely Wash with a non abrasive all purpose cleaner and water then rinse Wipe dry Never use cleaners with strong chemicals such as toilet bowl cleaners rust removers ceramic cook top cleaners laquer thinners or oven cleaners To remove persistent stains use a Scotch Brite pad and an abrasive cleaner or a solution of household bleach and water 1 part water to 1 part bleach To remove rust sta...

Страница 14: ...ge 14 of 16 Part 6216 014 000 Date 03 07 19 INSTALLATION OPERATIONS MAINTENANCE MANUAL NEO METRO FIELD SERVICE TOLL FREE 800 743 8259 LOCAL 626 855 4866 FAX 626 855 4863 Please visit for most current specifications www neo metro com Deck Mounted Short Faucet Dyson Airblade Wash Dry 3040 091 000 ST70 12 1 2 NPT Mixing Valve ST70 12 Valve Bracket Assembly 7802 101 001 7842 020 001 MOUNTING HARDWARE ...

Страница 15: ...MBLY 9 VDC Battery Pak Assy 6 AA Batteries Not Included Battery Pak Mounting Bracket 0710 358 001 6155 013 199 P Trap Enclosure 6216 200 002 Page 15 of 16 PDM SOAP OPTION Soap Filler Assembly 1391 008 001 Part 6216 014 000 Date 03 07 19 INSTALLATION OPERATIONS MAINTENANCE MANUAL NEO METRO FIELD SERVICE TOLL FREE 800 743 8259 LOCAL 626 855 4866 FAX 626 855 4863 Please visit for most current specifi...

Страница 16: ...inspection Acorn will not be liable for the cost of repairs alterations or replacement or for any expense connected therewith made by the owner or his agents except upon written authority from the Acorn City of Industry office Acorn will not be liable for any damages caused by defective materials or poor workmanship except for replacements as above provided Contact local Acorn Representative for c...

Отзывы: