Neo Instruments VENTILATOR Скачать руководство пользователя страница 21

21

IV. SPECIFICATIONS 

 
Signal processing 

 

32 Bit SHARC DSP 

Analog Digital Conversion  

48khz, 24 Bit  

Digital Analog Conversion  

48khz, 24 Bit 

Noise Level 

 

 

-80 dBA 

Input Sensivity    

 

-10 dBV (Hi), 0 dBV (Lo) 

Input Impedance  

 

1MOhm 

Output Level 

 

 

+6 dBV   

Output Impedance 

 

100 Ohms 

Recommended Load Impedance  10 KOhms or more 
Weight 

1.1kg / 2 lbs 7 oz (without 
Power Supply) 

Dimensions (W x D x H)   

192 x 153 x 55mm 

Mains Voltage 

 

 

100V-240V, 47Hz-63Hz 

Current Draw  

 

 

< 300mA 

Connectors  

Input Mono (Stereo Bypass 
optional) 
Output L 
Output R / Mono 
Remote 

Controls 

   Speed 

Trim 

Acceleration Trim 
Rotor Balance 
Drive Gain 
Mic Distance 
Effect Bypass 
Slow / Fast 
Hi / Lo Gain 
Git / Key (Speaker 
Simulation on / off) 

Options 

Ventilator Remote switch 
Halfmoon Switch CU-1 
 

Subject to change without notice. 

Содержание VENTILATOR

Страница 1: ...BEDIENUNGSANLEITUNG OWNER S MANUAL MODE D EMPLOI...

Страница 2: ...EINSTELLUNGEN 4 III BEDIENELEMENTE 7 IV TECHNISCHE DATEN 10 V SICHERHEITSHINWEISE 11 VI GARANTIEBEDINGUNGEN 12 Die in dieser Bedienungsanleitung benutzten Markennamen Hammond und Leslie sind gesch tz...

Страница 3: ...ende herausragende Merkmale aufw ndige Modeling Algorithmen exakte Nachbildung des Rotoreffekts eines 122er Leslies unabh ngige Simulation von Bass und Hochtonrotor genaue Reproduktion der mechanische...

Страница 4: ...t die Stellung Lo sowohl f r Orgel Keyboards als auch Gitarre richtig Nur f r sehr leise Gitarren oder Keyboards mit schwachem Output wird es n tig sein auf Hi umzuschalten Der Ausgangspegel bleibt in...

Страница 5: ...en Der interne Slow Fast Taster bleibt dabei weiterhin aktiv Key Git In der Stellung KEY ist die Speaker Simulation des VENTILATOR eingeschaltet Sie reproduziert exakt den Frequenzgang eines 122er Les...

Страница 6: ...lich das mitgelieferte Netzteil 12V DC 2A anschlie en Der VENTILATOR kann nicht mit Batterien betrieben werden UNBEDINGT BEACHTEN Um st rungsfreien Betrieb zu gew hrleisten sollten Sie alle Anschl ss...

Страница 7: ...m Taster wird der Rotoreffekt an und ausgeschaltet Im Bypassbetrieb leuchtet die zugeh rige rote LED Effekt aus und das Eingangssignal wird per Relais auf beide Ausg nge geschaltet True Bypass Slow Fa...

Страница 8: ...celeration Hier wird die Zeit eingestellt die beide Rotoren brauchen um von Slow auf Fast oder von Fast auf Slow zu wechseln Linksanschlag des Reglers bewirkt die k rzeste Beschleuni gung bzw Abbremse...

Страница 9: ...der Orgel auf Maximum gebracht und der Drive Regler am VENTILATOR auf die gew nschte maximale Verzerrung eingestellt Mit dem Volume Pedal der Orgel kann die Verzerrung nun komfortabel und ausdruckssta...

Страница 10: ...Anschlusswert 10 KOhm oder mehr Gewicht 1 1kg ohne Netzteil Abmessungen B x T x H 192 x 153 x 55mm Netzspannung 100V 240V 47Hz 63Hz Stromverbrauch max 300mA Anschl sse Eingang Mono Stereo Bypass opti...

Страница 11: ...eneinstrahlung aussetzen Nur mit dem mitgelieferten Netzteil und nur mit den angegebenen Netzspannungen betreiben Ger t keinen Ersch tterungen und harten St en aussetzen Zum Schutz des Ger tes bei Gew...

Страница 12: ...d gemacht werden Die Garantieleistung bezieht sich nicht auf Transportsch den auch nicht auf Sch den durch Nichtbeachtung der Bedienungsanleitung und fehlerhafter oder nachl ssiger Behandlung des Ger...

Страница 13: ...13...

Страница 14: ...TIONS AND CONTROL SETTINGS 16 III CONTROL FEATURES 18 IV SPECIFICATIONS 21 V SAFETY GUIDELINES 22 VI WARRANTY TERMS 23 The brand names Hammond and Leslie used in this operating manual are protected tr...

Страница 15: ...nd guitar its outstanding features include Sophisticated modeling algorithms and a faithful replication of the model 122 Leslie s rotary effect Independent emulations of bass and treble rotors Faithfu...

Страница 16: ...a constant level at both settings The Overload LED serves as a level meter Overload LED This LED lights up to indicate the input or output signal level has reached the circuit s threshold For the bes...

Страница 17: ...l sound system such as studio monitors high quality stage monitors and PA cabinets If you are using a guitar plugged into a guitar amp set the switch to GIT to disable the speaker simulation The devic...

Страница 18: ...tomp switch turns the rotary effect on and off Its red LED lights up when the device is bypassed effect off and the input signal is relayed to both outputs via a true bypass circuit Slow Fast This sto...

Страница 19: ...adjusts the amount of time it takes both rotors to go from slow to fast and from fast to slow Set the knob to the far left for the fastest acceleration and deceleration time Twist it to the right and...

Страница 20: ...NTILATOR s Drive knob to dial in the maximum distortion level This lets you ride the organ s volume pedal to control the amount of saturation which is a convenient and musically expressive way of modu...

Страница 21: ...Impedance 10 KOhms or more Weight 1 1kg 2 lbs 7 oz without Power Supply Dimensions W x D x H 192 x 153 x 55mm Mains Voltage 100V 240V 47Hz 63Hz Current Draw 300mA Connectors Input Mono Stereo Bypass...

Страница 22: ...the included AC adapter and the indicated mains voltages only Do not expose the device to vibrations and hard shocks Pull the power plug when the device is unsupervised for longer periods and to prot...

Страница 23: ...ect or deliver a replacement has failed The warranty does not cover damage incurred during transit as well as damage caused by non compliance with the operating manual and improper or negligent handli...

Страница 24: ...GLAGES 26 III ELEMENTS DE COMMANDE 29 IV DONN ES TECHNIQUES 33 V CONSIGNES DE S CURIT 34 VI CONDITIONS DE GARANTIE 35 Les noms de marque Hammond et Leslie mentionn s dans cette notice d utilisation so...

Страница 25: ...ct ristiques uniques suivantes algorithmes de mod lisation complexes reproduction l identique de l effet de rotation d une cabine Leslie 122 simulation ind pendante du rotor des graves et du rotor des...

Страница 26: ...position Lo convient aussi bien aux orgues claviers qu aux guitares La position Hi n est n cessaire que pour les guitares ayant un volume sonore tr s faible ou pour les claviers ayant un signal de so...

Страница 27: ...Slow Fast interne reste enclench Key Git La position KEY permet d activer la simulation de haut parleur du VENTILATOR Elle reproduit l identique la r ponse en fr quence d une cabine Leslie 122 La sim...

Страница 28: ...le bloc d alimentation 12V DC 2A fourni Le VENTILATOR ne peut pas fonctionner avec des piles A OBSERVER IMP RATIVEMENT Afin de garantir un fonctionnement sans dysfonctionnements veuillez proc der tout...

Страница 29: ...r les guitares mettre ce m me bouton en position GIT Bypass Ce bouton poussoir vous permet d activer ou de d sactiver l effet de rotation En mode Bypass la LED rouge correspondante s allume effet d sa...

Страница 30: ...n Cette section permet de r gler le temps n cessaire aux deux rotors pour passer de Slow Fast ou de Fast Slow Lorsque le potentiom tre est tourn compl tement vers la gauche les temps d acc l ration de...

Страница 31: ...ni re optimale tel que d crit au paragraphe LED Overload Amener ensuite la p dale de volume de l orgue son maximum puis r gler le potentiom tre Drive du VENTILATOR sur la distorsion maximale souhait e...

Страница 32: ...e la cabine Leslie Lorsque le potentiom tre Distance est tourn vers la droite le son contient moins de modulations d amplitude la mani re d une configuration studio lorsque les micros sont plac s 1 2...

Страница 33: ...charge recommand e 10 KOhm ou plus Poids 1 1kg sans le bloc d alimentation Dimensions L x P x H 192 x 153 x 55mm Tension de secteur 100V 240V 47Hz 63Hz Consommation lectrique max 300mA Connexions Ent...

Страница 34: ...pas exposer l appareil au rayonnement solaire direct N utiliser l appareil qu avec le bloc d alimentation fourni et avec la tension de secteur indiqu e Ne pas exposer l appareil aux secousses ou aux...

Страница 35: ...La garantie ne couvre pas les dommages li s au transport ni aux dommages engendr s par le non respect de la notice d utilisation ou lorsque l appareil a t manipul de mani re incorrecte ou avec n glig...

Отзывы: