background image

 
 

 
 
 
 

 
 
 

 
 
 

 
 
 

E-WIZ

GOOD

CHECK

BAD

POWER

ON

FENCE

GATE

SERVICE

STATUS

FENCE

ELECTRIC FENCE ENERGIZER

 

 

GROUP OF COMPANIES

 

USER MANUAL

 

WIZORD 4 – 

Electric Fence Energizer

 

 

Содержание WIZORD 4

Страница 1: ...E WIZ GOOD CHECK BAD POWER ON FENCE GATE SERVICE STATUS FENCE ELECTRIC FENCE ENERGIZER GROUP OF COMPANIES USER MANUAL WIZORD 4 Electric Fence Energizer ...

Страница 2: ...D 4 USER MANUAL Table of Contents INTRODUCTION 3 COMPANY PROFILE 3 GUARANTEE 4 STANDARD OPERATING PROCEDURES 5 STANDARD OPERATING PROCEDURES Notes 6 STANDARD OPERATING PROCEDURES LED s 7 FEATURES FUNCTIONS 8 9 ...

Страница 3: ...ormation on our products SABS test reports and general information is available on our web site at http www nemtek com C O M P A N Y P R O F I L E The NEMTEK Group of Companies manufacture and distribute intelligent electronic security and perimeter control systems and have been involved in the security industry since 1990 We have our own research and development team designing and manufacturing a...

Страница 4: ...Africa OR Nemtek Security Warehouse Unit 4 Meadowdale Park Cnr Herman Dick Kemp Roads Meadowdale Edenvale Gauteng South Africa The buyer shall pay all shipping and other charges for the return of the product to Nemtek or Nemtek Security Warehouse L I M I T A T I O N O F G U A R A N T E E The guarantee does NOT apply to defects resulting from acts of GOD modifications made by the buyer or any third...

Страница 5: ... the battery may run low and cause the service light to flash If the mains interruption is sufficiently long the unit will shut down and there will be no indication of mains failure TOGGLE FUNCTION In the event of the unit being switched off by the plastic tab while a fault is active the unit will silence all alarms On turning the unit on again the corresponding LED s will indicate the fault but n...

Страница 6: ...i annual basis 2 A functional energizer will only turn itself off under two conditions namely prolonged mains failure where battery damage has occurred or abnormal heat being generated within the energizer 3 There are no user serviceable parts within the energizer Please refer all problems to qualified service personnel 4 It is possible that under mains failure conditions the energizer will operat...

Страница 7: ...rging Fence energized No fence alarm No gate alarm No service condition If all are flashing fence is operating correctly Restore mains see Note 1 Turn energizer on see Note 2 Alarm condition Alarm condition Possible installer intervention required see Note 3 Check later see Note 4 Concern see Note 4 Service fence see Note 4 Service fence Alarm Fence faulty LED OFF LED PERMANENTLY LIT Fault occurre...

Страница 8: ...oltage and mains ground INTERFERENCE SUPPRESSION LOW EMI RADIATION The unit has been tested to comply with the latest international requirements CISPR14 2 1997 REMOTE KEY SWITCH The energizer can be wired to a remote on off switch There is only one external input and the selection of gate or remote on off is exclusive EARTH LOOP MONITORING For additional security the facility to use earth loop mon...

Страница 9: ...igh quality weather resistant material ARMED RESPONSE RADIO CONNECTABLE The system has the facility to be connected to an armed response radio BATTERY BACKUP The unit is supplied standard with a 12V 7AH rechargeable battery UNIT UPGRADEABLE The unit can be upgraded to allow Ø High low voltage fence monitoring Ø Multiple keypad pin numbers Ø Energizer synchronization Ø Programmable fence voltage Ø ...