Mini Tower Assembly: 

1.

 

Unpack all parts and hardware 

2.

 

Assemble the center post by bolting the handle to the top and bottom portions of the 

center post 

3.

 

Attach the rectangular bottom plate to the center post 

4.

 

Attach Typhon™ Fixtures 

a.

 

For Three Typhon™ Fixtures use the holes for the 

triangular configuration: 

b.

 

Ensure the handle will be centered between Typhon™ 
fixtures as pictured. Ensure the Typhon™ fixtures are 

positioned correctly.  

 

5.

 

Bolt Typhon™ fixtures into the bottom plate 

6.

 

Once all Typhon™ Fixtures are mounted to the bottom plate, line up the holes at the top 

of the fixture with the corresponding holes on the top plate.  

7.

 

Utilize the HARDWARE to attach the Typhon™ Fixtures to the Top Plate 

8.

 

Once all fixtures are attached to the top plate, secure the top plate with the center bolt. 

9.

 

The Mini Tower is built! Take a moment to ensure all hardware is properly attached to 

the fixture. 

 

If you have any issues, contact Nemesis™ Customer Support at: 

(469)-466-2UVC

 

Power 

1.

 

Included with your Mini Tower is 1 Power Cable and 3 Power Jumpers to power the 

Typhon™ fixtures 

2.

 

The Power Cable needs to be plugged into the Tru1 POWER IN connection on the side 

with the Red Buzzer 

3.

 

The Power Jumpers: 

a.

 

One end will plug into the “POWER OUT” connection on the sensor side 

(opposite the POWER IN on the Buzzer Side) 

b.

 

The other will plug into the POWER IN connection on the adjacent fixture.  

c.

 

Repeat this process until all Typhon™ units have power 

d.

 

one 

 

 

 

 

Содержание Mini Typhon Tower

Страница 1: ...Mini Typhon Tower USER MANUAL English ...

Страница 2: ...of Contents Safety 3 Unpacking 9 Customer Support 9 Limited Warranty 10 Benefits of UV C Technology 11 UV C Disclaimer 11 General Guidelines 12 Fixture Overview 13 How do I use my Typhon 14 Disinfectant Times 15 Cleaning 16 Replacing Radiators 16 ...

Страница 3: ...EAD AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS a This equipment is designed for use with germicidal UV radiation sources and must be installed in compliance with competent technical directions to prevent risk of personal injury from UV radiation b UV and optical radiation can be reflected by surrounding surfaces such as ceilings and walls Since the reflective properties of surfaces...

Страница 4: ...orary damage to the eye can be an effect of exposure to UV C light Long term exposure may produce fading or degradation of some materials Amounts of degradation are completely dependent on types and quality of materials and if they have UV C protection built in The FDA approved waivers on UV A UV B and UV C more information is available from the FDA at https www fda gov media 136533 download For t...

Страница 5: ...me germicidal ultraviolet rays may break down plastic rubber or other non metallic materials can fade colors and can be damaging to plant life Shield all plastic rubber or other non metallic parts plant life etc which may be exposed to direct or reflected germicidal ultraviolet rays 10 Do not operate equipment if the power cord and or plug are damaged or if any other damage to the unit is visible ...

Страница 6: ...Warning indicates a potentially hazardous situation which if not avoided could result in death or serious injury Caution indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury Caution used without the safety alert symbol indicates a potentially hazardous situation which if not avoided may result in property damage This symbol pictorial is used to id...

Страница 7: ...onents which must not be disposed of in the trash Product safety labels should be periodically inspected and cleaned as necessary to maintain good legibility Always replace illegible safety labels Contact the factory to obtain replacement safety labels Hg RADIATORS CONTAIN MERCURY manage in accord with disposal laws see LampRecycle org OR contact Nemesis Email support nemesisuvc com Phone 469 466 ...

Страница 8: ...Yoke 2 Yoke Knobs w rubber washers 1 Power Cable 1 Manual ATTENTION Operator MUST READ ENTIRE MANUAL before attempting to operate the fixture Failure to follow instructions guidelines laid out in this manual will void the warranty and could lead to physical harm Customer Support The customer support line is available for any inquiries on your product Visit https www nemesisuvc com or call 469 466 ...

Страница 9: ...nd this warranty does not include routine cleaning or periodic check up 3 Nemesis reserves the right to make changes in design and or performance improvements upon its products without any obligation to include these changes in any products manufactured prior 4 This is the only written warranty applicable to this product and supersedes all prior warranties and written descriptions of warranty term...

Страница 10: ...sold pursuant to this Agreement must be installed correctly and used properly to be effective Nemesis is not responsible for improper installation usage or damages caused by the end user Nemesis makes no representations guarantees or assurances as to the final effectiveness of using a UV C lighting system for sanitization Nemesis warrants that with proper installation and usage scientific evidence...

Страница 11: ...can cause the coating on the radiator to deteriorate Light dusting can be done carefully with a fresh dry lint free cloth Be careful when replacing radiators Check fixtures for dust at least once a month Routine cleaning can be done with a fresh dry lint free cloth or with an air compressor at very low psi See page 16 for more detailed instructions on cleaning your Typhon Take care when cleaning d...

Страница 12: ...alerts during use Visual alerts during use Safe and environmental No harsh chemicals No landfill Designed in the USA Manufactured in the USA Ships from the USA Lamp Source TUV 55 W HO lamp technology Dimensions Height 49 5 T x 10 5 W Weight 29 5 lbs Input voltage AC 90 120V 50 60Hz 1 6 A Rating Indoor use only UV C Radiator LED Indicator True1 Connection IN True1 Connection OUT Yoke Knob Nemesis L...

Страница 13: ...infecting See page 10 to determine disinfection time Step 4 Ensure the area being disinfected is clear of any occupants animals or other living things Step 5 Plug in send power to the fixture to begin disinfection Step 6 You will hear an alert running as soon as the system starts The disinfection time starts one minute from activation Then run for the determined amount of time based on distance an...

Страница 14: ...Time calculated to reach 120 Joules of disinfection Note Times are calculated but may not be 100 accurate for specific rooms A specific measurement for your space is necessary for complete efficacy and efficiency Feet from Typhon Time Minutes 1 1 2 1 3 1 4 2 5 3 6 5 7 7 8 9 9 11 10 13 11 16 12 19 13 23 14 26 15 30 16 35 17 39 18 44 19 49 20 54 21 60 22 65 23 71 24 78 25 84 120 Joules ...

Страница 15: ...the back of the fixture Then slide the Nemesis light guard up and off of the fixture This will allow you to access the radiators DO NOT touch radiators with bare hands oils from the skin will deteriorate the coating on the outside of the glass use sterile gloves and eye protection when working with radiators Twist the top and bottom of the radiator turn to unlock the radiator from the socket Remov...

Страница 16: ...ponding holes on the top plate 7 Utilize the HARDWARE to attach the Typhon Fixtures to the Top Plate 8 Once all fixtures are attached to the top plate secure the top plate with the center bolt 9 The Mini Tower is built Take a moment to ensure all hardware is properly attached to the fixture If you have any issues contact Nemesis Customer Support at 469 466 2UVC Power 1 Included with your Mini Towe...

Страница 17: ...Nemesis UV C Typhon User Manual_V1 1 17 User Manual Version 1 2 Updated 12 28 2020 www nemesisuvc com 469 466 2UVC ...

Отзывы: