1 |
P a g e
December 22, 2020
Safety precautions:
•
This equipment contains a refrigeration system charged with R290 Propane
flammable refrigerant.
•
Do not plug in the unit if you observe freight damage.
•
For electrical requirements, Refrigerant Charge amount and Model Name, see the
Data Tag and labels located on the end exterior panel.
•
Carefully read all labels attached to the unit prior to plugging it into an electrical outlet.
CAUTION
–
Risk of Fire or Explosion. Flammable Refrigerant Used. Follow Handling Instructions
Carefully in Compliance with U.S. Government Regulations. R290 Refrigerant
CAUTION
–
Risk of Fire or Explosion. Flammable Refrigerant Used. Consult Repair
Manual/Owner’s Guide Before Attempting To Install or Service This Product. All Safety Precautions
Must Be Followed. R290 Refrigerant
DANGER
–
Risk of Fire or Explosion. Flammable R290 Refrigerant Used. Do Not Use Mechanical
Devices to Defrost Refrigerator. Do Not Puncture Refrigerant Tubing. R290 Refrigerant
DANGER
–
Risk of Fire or Explosion. Flammable Refrigerant Used. To Be Repaired Only by
Trained Service Personnel. Do not Puncture Refrigerant Tubing. R290 Refrigerant
CAUTION
–
Risk of Fire or Explosion. Dispose of Properly in Accordance with Federal or Local
Regulations. Flammable Refrigerant Used. R290 Refrigerant
CAUTION –
Risk of Fire or Explosion. Due to Puncture of Refrigerant Tubing; Follow Handling
Instructions Carefully. Flammable Refrigerant Used. R290 Refrigerant
NOTE:
•
We strongly recommend all preventive maintenance and servicing be performed by qualified HVAC
Technicians.
•
Leak check with Combustible Gas Detector before and after any Servicing.
•
Unplug unit before Servicing.
•
If the supply cord is damaged, it must be replaced by a special cord or assembly available from the
manufacturer, or its service agent.
•
Component parts shall be replaced with OEM parts only.
•
Freezer must be plugged into its own individual electric circuit, which has an amp rating that
matches the data tag on the cabinet.
•
DO NOT, under any circumstances, cut or remove the ground prong from the power cord. For
personal safety, this appliance must be properly grounded. Do not plug into two prong outlets.
•
DO NOT, under any circumstances, use adaptor plugs or extension cords.
•
Use this freezer for its intended purpose as described in this manual.
Installation and Operating Instructions:
•
NSF standards require cabinet to be installed with casters, 6” legs, or sealed to the floor with an
NSF approved silicone sealant.
•
Before using the equipment, inspect for freight damage. Refuse delivery if there is any damage.