Nelson Irrigation Corporation 848 Airport Rd. Walla Walla, WA 99362-2271 USA Tel: 509.525.7660 Fax: 509.525.7907 [email protected] Web site: www.nelsonirrigation.com
8/12
SR200 OPERATION & AdjUSTmENT
2.
Install Nozzle on end of Range Tube. If using
a Ring Nozzle, Install desired Ring size in cap.
Assure Ring is centered. Ring Nozzle cap and
Nozzle can be sufficiently tightened by hand.
3.
Adjust location of Reverse Stops to give desired
arc of coverage. Stops must be mounted such
that the arrows point towards each other with
the Trip Lever located between them. If the Stops
are set incorrectly on the wrong end of the arc,
the sprinkler will fail to reverse.
4.
The SR200 is factory set for normal rotation
speed. If a faster or slower speed is desired,
move the Arm Weight backward for faster
operation or forward for slower operation.
5.
The SR200 is capable of using a Secondary Nozzle
for in-close coverage. To use this feature, remove
the supplied 6201 plug and replace with the 7RN
Series Nozzle of your choice. The supplied 7V Vane
must be used to maintain proper stream integrity.