N550c Weld Cycle Timing
The Arc Charger series controls the main current and the weld gun using a combination of settings. For short
cycle welding, the gun drop time and plunge time are critical components in the weld timing, so they must be
configured, understood, and used correctly to get the optimum results.
Here are the relevant settings for welding on the N550c:
F31
– Drop time.
Use this function to measure \ configure the drop time of the gun. While viewing this function
(that is, with F31 on the display), attempt a weld. The gun will lift and drop, but no weld current will pass. The
gun’s drop time is measured, stored, displayed, and used in weld timing as will be described later in this
document.
F2
– Plunge short circuit on-time.
This is the time that the weld current re-input power on after the stud is
scheduled to have made contact with the workpiece.
Front Panel Time.
This is the (weld) time set on the front panel.
Here are some other definitions:
Main current time = Front panel time + Plunge short circuit on-time (F2).
The main current time is the total
time that weld current is delivered. See below. Under normal conditions, critical times and events throughout
the main current time can be described in the following weld profile.
Содержание ArcCharger N550C DOMESTIC
Страница 11: ...Part No 729 110 040 Rev 1 41 June 2016 2016 Nelson Stud Welding Inc All Rights Reserved 10 1 5 1 Dimensions ...
Страница 18: ...Part No 729 110 040 Rev 1 41 June 2016 2016 Nelson Stud Welding Inc All Rights Reserved 17 ...
Страница 60: ...Part No 729 110 040 Rev 1 41 June 2016 2016 Nelson Stud Welding Inc All Rights Reserved 59 ...
Страница 62: ...Part No 729 110 040 Rev 1 41 June 2016 2016 Nelson Stud Welding Inc All Rights Reserved 61 ...
Страница 64: ...Part No 729 110 040 Rev 1 41 June 2016 2016 Nelson Stud Welding Inc All Rights Reserved 63 ...