HEATER & THERMOSTAT INSTALLATION DIA
G
RAMS
STRAIN RELIEF CONNECTOR
ELECTRICAL
JUNCTION BOX
WATER
SPOUT
TUBE
HEATING
ELEMENT
(BELOW
CROSS BEAM)
HOLE IN
CROSS BEAM
HEAT SHEILD
CERAMIC
INSULATORS
THERMOSTAT
ELECTRICAL JUNCTION BOX COVER:
• Replace old cove
r
with
n
ew cove
r
p
r
ovided with heate
r
s & the
rm
ostats.
THERMOSTAT IS LOCATED IN ELECTRICAL JUNCTION BOX
AS INDICATED IN DIA
G
RAM.
STRAIN RELIEF CONNECTOR PREVENTS HEATER CORD FROM BEIN
G
PULLED OUT OF JUNCTION BOX. SEE INSTRUCTIONS BELOW.
•Locate Co
nn
ecto
r
o
n
heate
r
co
r
d with la
r
ge head of Co
nn
ecto
r
o
n
heati
n
g
ele
m
e
n
t side. Allow e
n
o
u
gh co
r
d o
n
j
un
ctio
n
box side fo
r
wi
r
e
co
nn
ectio
n
s to be
m
ade i
n
side j
un
ctio
n
box.
•I
n
se
r
t Co
nn
ecto
r
a
n
d heate
r
co
r
d i
n
j
un
ctio
n
box (as i
n
dicated i
n
diag
r
a
m
)
u
si
n
g plie
r
s a
n
d fi
n
ge
r
s
un
til Co
nn
ecto
r
s
n
aps i
n
place.
•Test by p
u
lli
n
g o
n
heate
r
co
r
d towa
r
d heati
n
g ele
m
e
n
t. Co
nn
ecto
r
a
n
d
heate
r
co
r
d sho
u
ld
n
ot p
u
ll o
u
t of j
un
ctio
n
box.
POWER SUPPLY MUST PROVIDE:
•A HOT wi
r
e which is co
nn
ected to
r
e
m
ai
n
i
n
g BLACK wi
r
e of the
rm
ostat.
•A NEUTRAL wi
r
e which is co
nn
ected to WHITE wi
r
e of heate
r
.
•A
G
ROUND wi
r
e which
mu
st be co
nn
ected to the g
r
o
un
d sc
r
ew i
n
the
ha
n
dy box. This will g
r
o
un
d both the wate
r
e
r
a
n
d the heati
n
g ele
m
e
n
t.
INTENDED USE:
• The
rm
ostat Pa
r
t 758 is desig
n
ed fo
r
both Models 730 & 760.
• Heate
r
Pa
r
ts 755C & 755HA a
r
e desig
n
ed fo
r
Model 730 Wate
r
e
r
s o
n
ly.
• Heate
r
Pa
r
ts 785C & 785HA a
r
e desig
n
ed fo
r
Model 760 Wate
r
e
r
s o
n
ly.
• Heate
r
’s Pa
r
ts 755C & 785C co
m
e with Heati
n
g Ele
m
e
n
t, Heat Shield,
Ce
r
a
m
ic I
n
s
u
lato
r
s, St
r
ai
n
Relief Co
nn
ecto
r
a
n
d Cove
r
fo
r
J
un
ctio
n
Box.
• Do
n
ot
u
se fo
r
a
n
y othe
r
applicatio
n
.
WARNING!
ELECTRICAL INSTALLATION
& MAINTENANCE
HEATER #
755
785
A LICENSED ELECTRICIAN WILL DETERMINE
:
A)
Type and size of service wire,
B)
grounding procedure,
and C) proper fusing of heater.
GROUND WIRE:
The heating element is grounded to the
waterer by a green ground screw at the factory. The ground wire
from the power service should be secured to the waterer with
the second green ground screw provided in the handy box. When
using wire-nuts, follow instruction on wire-nut box. Tape wire
nuts to wire to prevent loosening.
FUSING
:
Waterers must be individually fused. Do not over fuse.
Consult a licensed electrician. Heating rating @ 120 volts AC.
DEDICATED CIRCUITS
– Waterers must be on dedicated
circuits. TURN POWER OFF after the Winter heating season when
heaters are no longer needed (temperatures are consistently
above freezing) or when performing maintenance on waterers.
Use a licensed electrician to install and maintain the
Waterer, so you can be assured that you have complied
with all national and local electrical codes and that you
have not created a risk of electrocution or fire. Improper
installation or maintenance may result in serious injury or
death for personnel or animals or damage to structures.
Heate
r
& The
rm
ostat Wi
r
i
n
g Diag
r
a
m
WARNIN
G
!
TURN OFF ELECTRICITY WHEN SERVICIN
G
WATERER
Always t
urn
off powe
r
to wate
r
e
r
s whe
n u
si
n
g a tool to se
r
vice o
r
m
ai
n
tai
n
wate
r
e
r
to eli
m
i
n
ate
r
isk of elect
r
oc
u
tio
n
. Wate
r
e
r
s sho
u
ld be o
n
dedicated ci
r
c
u
its.
WARNIN
G
!
USE CARE NOT
to spill wate
r
o
n
heati
n
g ele
m
e
n
t. Wate
r
o
n
heati
n
g ele
m
e
n
t
r
ed
u
ces heate
r
life a
n
d
m
ay lead to f
r
eeze-
u
p. Keep a
r
ea
below d
r
i
n
ki
n
g bowl as d
r
y a
n
d clea
n
as possible.
TOP VIEW:
COVER & BOWL REMOVED
ELECTRICAL
JUNCTION BOX
QUESTIONS?
Pho
n
e: 888-844-6606
Mo
n
day-F
r
iday 7:30-5:00 CST