1.  Control valve stalled in regeneration   A.  Motor not operating  

A.   Replace Motor

 

 

B.   No electric power at outlet  

B.   Repair outlet or use working outlet 

 

 

C.   Defective transformer  

C.   Replace transformer

 

 

D.   Defective PC board  

D.   Replace PC board

 

 

E.   Broken drive gear or drive cap assembly  

E.   Replace drive gear or drive cap assembly

 

 

F.   Broken piston retainer  

F.   Replace drive cap assembly

 

 

G.   Broken main or regenerant piston  

G.   Replace main or regenerant piston 

2.  Control valve does not regenerate  

A.   Transformer unplugged  

A.   Connect transformer

 

automatically when REGEN button   B.   No electric power at outlet  

B.   Repair outlet or use working outlet

 

is depressed and held  

C.   Broken drive gear or drive cap assembly  

C.   Replace drive gear or drive cap assembly

 

 

D.   Defective PC board  

D.   Replace PC board

3.  Control valve does not regenerate  

A.   Bypass valve in bypass position  

A.   Put control valve in service position

 

automatically but does when  

B.   Meter connection disconnected  

B.   Connect meter to PC board

 

REGEN button is depressed  

C.   Restricted/stalled meter turbine  

C.   Remove meter and check for free rotation

 

 

  or foreign matter 

 

 

D.   Programming error  

D.   Check control valve set-up procedure

 

 

E.   Defective meter  

E.   Replace meter

 

 

F.   Defective PC board  

F.   Replace PC board

4.  Time of day flashes on and off  

A.   Battery back-up maintains time-of-day up  

A.   Reset time of day and replace battery on PC Board

 

 

  to 2 years in event of power outage and  

  (Lithium coin type battery 2032)

 

 

  battery is not depleted. Time of day flashes

 

 

  when battery is depleted.

 

 

B.   Prior to 2/2007, PC board did not have  

B.   Reset time of day.

 

 

  battery back-up - capacitor held time of day

 

 

  up to 2 hours. Power outage > 2 hours.

5.  Softener delivers hard water.  

A.   Bypass valve is open or faulty.  

A.   Close bypass valve or replace.

 

 

B.   No salt or low salt level in brine tank.  

B.   Add salt to brine tank and maintain salt level

 

 

   

  above water level.

 

 

C.   Softener fails to draw brine.  

C.   See problem #10.

 

 

D.   Excessive water usage.  

D.   Check gallon capacity settings.

 

 

E.   Insufficient brine level in brine tank.  

E.   Check brine refill setting and refill flow restrictor  

 

 

   

  for blockage.

 

 

F.   Resin level inadequate.  

F.   See problem #7.

 

 

G.   Meter faulty.  

G.   Test meter and clean or replace meter.

 

 

H.   Raw water hardness fluctuation.  

H.   Test raw water hardness and adjust settings to

 

 

  highest known hardness.

6.  Unit uses too much salt.  

A.   Improper brine refill setting.  

A.   Check brine refill setting for proper salt dosage

 

 

B.   Improper settings.  

B.   Check water hardness and reevaluate capacity  

 

 

   

  setting specification

 

 

C.   Excessive water in brine tank.  

C.   See problem #9.

 

 

D.   Leaking faucets, toilets, etc...  

D.   Repair or replace those items.

 

 

E.   Brine line flow control out of place  

E.   Replace Brine line flow control.

7.   Loss of resin.  

A.   Backwash controller missing.  

A.   Install backwash controller.

 

 

B.   Faulty distributor tube assembly.  

B.   Check distributor tube assembly for cracks or holes.

 

 

C.   Air being drawn in through brine system.  

C.   Check for leaks in brine lines, fittings, or air check.

 

 

   

  Repair or replace.

 

 

D.   Air in water supply system  

D.   1. Install upper distributor if missing.

 

 

   

  2. Ensure that water supply system has an air

 

 

   

      eliminator.

8.   Softener delivers salty water.  

A.   Low water pressure.  

A.   Check incoming water pressure - Must remain at

 

 

   

  minimum of 25 psi.

 

 

B.   Excessive water in brine tank.  

B.   See problem #9.

 

 

C.   Wrong size injector.  

C.   Install correct injector.

9.   Excessive water in brine tank.  

A.   Plugged injector.  

A.   Remove injector and clean ports.

 

 

B.   Faulty piston/seal assembly.  

B.   Replace piston/seal assembly.

 

 

C.   Plugged or kinked drain line.  

C.   Correct any kinking or plugging of drain line.

 

 

D.   Backwash flow controller closed off.  

D.   Check backwash flow controller.

 

 

E.   Defective brine line flow control.  

E.   Replace brine refill flow control.

Troubleshooting

Содержание NWTS

Страница 1: ...1 1 1 4 1 1 2 2 Twin Control Valves NWTS Homeowners Guide...

Страница 2: ......

Страница 3: ...ssing again and releasing will cancel the regeneration Pressing and holding for 3 seconds will initiate an immediate regeneration Pressing while in regeneration will advance to the next cycle Pressing...

Страница 4: ...0 NOR BACKWASH AM CLOCK NEXT UP DOWN REGEN SET SOFTENING FILTERING REGEN TODAY NORMAL MIN x1000 NOR CAPACITY BACKWASH REMAINING GAL CLOCK NEXT UP DOWN REGEN SET FILTERING DAY NORMAL MIN x1000 NOR BACK...

Страница 5: ...rine Tank Control Valve Softener Tank Safety Brine Valve Air Check Ion Exchange Resin Distributor Tube Basket Distributor Single Tank Softener Air Injection Oxidation AIO Filter System Control Valve S...

Страница 6: ...hout adequate disinfection before or after treatment Water Conditioner Draining Procedure In cold weather climates it is common for plumbing systems that are not in use to be winterized or drained of...

Страница 7: ...ly piping was routed to the water softener control valve a water loop or trap may have been created Sometimes drain valve s are installed at the bottom of the loop to assure all water can be drained o...

Страница 8: ...m Memory Control can no longer operate properly due to a check sum error for the Programming Section of E2PROM memory 404 Diagnostic Memory Control can no longer operate properly due to a check sum er...

Страница 9: ...replace B No salt or low salt level in brine tank B Add salt to brine tank and maintain salt level above water level C Softener fails to draw brine C See problem 10 D Excessive water usage D Check ga...

Страница 10: ...splay A Transformer unplugged A Plug transformer into uninterrupted outlet B No electric power at outlet B Repair outlet or use working outlet C Defective transformer C Replace transformer D Battery 3...

Страница 11: ...dential use Water conditioners installed for commercial or industrial applications are guaranteed for one 1 year from the date of installation 2 Installation must be made in accordance with legal or l...

Страница 12: ...Nelsen Corporation Part No NWTS HOMEOWNERS GUIDE Rev 0519...

Отзывы: