3
Specifications
Model no.
V
Hz
Duct
diameter
Noise (sone)
Power
consumption
Speed (RPM)
Air direction at 0.1
”
WG
(CFM)
Weight
3291019
(BPT12-12D)
120
60
3”
(7.6 cm)
3.0
45 W
1,318
50 CFM
4.05 lb (1.84 kg)
3291026
(BPT12-13D)
120
60
3”
(7.6 cm)
4.5
45 W
1,620
70 CFM
4.05 lb (1.84 kg)
•
3291019 : Recommended for use in rooms up to 60 ft² (5,57 m²).
• 3291026 : Recommended for use in rooms up to 85 ft² (7,9 m²).
•
If the area is larger, it is recommended to use a fan providing a greater CFM.
Dimensions
Ceiling opening (L)
Ceiling opening (W)
Ceiling opening (D)
Housing dimension (L)
Housing dimension (W)
Housing dimension (D)
7
11
/
16
”
(19.5 cm)
7
1
/
2
”
(19 cm)
3
15
/
16
”
(10 cm)
7
1
/
2
”
(19 cm)
7
1
/
4
”
(18.4 cm)
3
11
/
16
”
(9.4 cm)
Note : Be careful to cut the hole exactly to ensure that the screen will cover it properly.
Safety information and warnings
1. Electric Service supply must be 120 volts, 60 hertz.
2. Do not install in locations where the air temperature will exceed
40°C (104°F).
3. Do not bend or kink the power wires.
4. Follow all local building, safety and electrical codes as well as NEC
(National Electrical Code) and OSHA (Occupational Safety
and Health Act).
5. Always disconnect the power supply prior to servicing the fan,
motor or junction box.
6. Protect the electrical wires from sharp edges, oil, grease,
hot surfaces, chemicals, or other objects.
7. Do not install the unit in ducts where the airflow can be
severely restricted.
8. There should always be an adequate air supply to the vented area.
9. This ventilating fan is approved for use over a bathtub or shower
when installed in a GFCI (Ground Fault Circuit Interrupter)-protected
circuit. Do not use fan over a bathtub or shower that is not approved
for that application and marked accordingly.
10. For general ventilating use only. Do not use to exhaust hazardous
or explosive materials and vapors.
11. Disconnect the appliance from the power supply before servicing.
12. Do not use this fan with any solid state control device, such as
a remote control, dimmer switch, or certain timers. Mechanical timers
are not solid state devices.
13. This product must properly connect to the grounding conductor
of the supply circuit.
14. Not for use in kitchens.
15. Ducted fans must always be vented to the outdoors. Do not vent
exhaust air in spaces within walls, ceiling, attic, crawl space
or garage.
7
1
/
4
” (18.4 cm)
10” (25.4 cm)
7
1
/
2
” (19 cm)
3
11
/
16
” (9.4 cm)
½” (1.2 cm)
3” (7.6 cm)
8
11
/
16
” (22 cm)
8
11
/
16
” (22 cm)
Содержание 3291019