5-3-2  Placing BETA Frame with Illuminator 

 

(1)   Place the main body of the Frame on your head after loosening the Strap, then adjust for 

optimum position of the Forehead pad and Nose pad. The Nose pad position is adjustable 

by sliding up and down and also forming the Nose pad to match your nose shape. Since 2 

types of Nose pads are provided with the Fame, choose either one for your comfort and 

convenience, according to your preference and the procedure to be performed.   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(2)  Squeeze the stopper of Strap to fit the body section of Frame to your head securely.   

 

(3)  Adjust the position of Illuminator by moving it up and down and/or right and left to obtain 

the optimum position. In order to observe with less shadow, bring the Illuminator closer to 

the Loupe’s optics 

 

(4)  If  the  Loupe  has  been  supplied,  adjust  the  position  of  Loupe  at  the  same  time  when 

adjusting the position of the Illuminator, referring to the Instruction Manual of the Loupe. 

 

 

 

Nose Pad 

Strap   

Strap Stopper 

Fig. 5-3-2 

Nose Pad 

Forehead Pad 

Illuminator 

Содержание Spot Illuminator NSI-III

Страница 1: ...o the field of vision during surgical diagnostic or therapeutic procedures This device has been designed for use with the NEITZ Binocular Loupe series and or NEITZ Frame series When necessary please r...

Страница 2: ...harging Batteries 12 5 2 Mounting Illuminator on Frame 13 5 2 1 Mounting Illuminator on Titanium Frame 13 5 2 2 Mounting Illuminator on BETA Frame 15 5 2 3 Mounting Illuminator on NEO Frame 16 5 3 Wea...

Страница 3: ...act Information 27 Annex A 28 Alarm System for Spot Illuminator NSI III 28 ANNEX B 29 EMC Guidance for Spot Illuminator NSI III 29 1 Guidance and Manufacturer s Declaration Electromagnetic Emissions 2...

Страница 4: ...ous situation which if not avoided could result in death or serious injury Used with the safety alert symbol indicates a potentially hazardous situation which if not avoided may result in minor or mod...

Страница 5: ...3 Safety Information 1 3 1 Common Precautions to All Devices Do not apply a strongly impact nor throw it It may cause injury or device failure Do not place on an unstable nor sloped surface It may re...

Страница 6: ...together with parts other than standard accessories including in this package Problems or damage may occur Do not operate in direct sunlight or harmful light Doing so may create high heat or damage of...

Страница 7: ...the device in a place where difficult to plug in out to from the wall outlet since the plug out from the outlet is one of the separation methods between the device and the battery charger Do not use t...

Страница 8: ...onnect the power plug of Illuminator from the battery case when the device will not be used for long periods of time to prevent from electrolyte leakage 1 4 Labeling on Outer Package The following lab...

Страница 9: ...instructions given in this manual Note 1 Two types of hinge are available one is for Titanium Frame and another is for BETA Frame or NEO Frame Either type of hinge has been mounted on the Illuminator...

Страница 10: ...ning Illuminator ON OFF and 5 5 2 Setting Illumination Brightness Wiring Ring Used to fix the Cord on the Temple Diaphragm Ring Changes the illumination field diameter by turning see 5 5 3 Adjusting I...

Страница 11: ...5 1 Turning Illuminator ON OFF Light Adjustment Switch Selects light intensity of High Middle or Low see 5 5 2 Setting Illumination Brightness Indicator for Residual Quantity Light Lights while illum...

Страница 12: ...ace Contacts the terminal of the battery Charge Indicator Lightens when charging and turns off when charging is complete Note The number of Indicator lights varies with the model of the charger provid...

Страница 13: ...ction manual for the specific Loupe with Frame purchased Examples of Combinations with Loupe BLS 3 and Various Frames 1 NEITZ Binocular Loupe BSL 3 with Titanium Frame 2 NEITZ Binocular Loupe BLS 3 wi...

Страница 14: ...does not leak organic electrolyte which is contained in the battery If electrolyte leakage occurs do not make contact with leakage and clean up with absorbent cloth and move the battery away from any...

Страница 15: ...e terminal of it as shown in Fig 5 1 1 3 Put all of batteries into the charger compartments taking care to observe polarity as indicated inside the charger 4 Swing out the Plug on the rear side of cha...

Страница 16: ...e to the Frame in the center shown in Fig 5 2 1 Note The removed washer shall be reused when the Illuminator will be mounted onto the Frame do not throw away 2 Affix the hinge on the Illuminator to bo...

Страница 17: ...le bow not so as to become stiff by using the supplied Wiring band as shown in Fig 5 2 4 in order to allow the Illuminator to move up and down vertically and right and left horizontally Handle the Cor...

Страница 18: ...to move up and down vertically and right and left horizontally If necessary to fix the Cord more add the Wiring ring or the Wring band s onto the strap as shown in Fig 5 2 6 Handle the Cord with care...

Страница 19: ...remove it temporarily 4 Pull the Forehead Cushion out of the center as shown in Fig 5 2 8 to remove it Set the Cord inside of the Forehead cushion as shown in Fig 5 2 9 then put back the cushion again...

Страница 20: ...r the Wring band s 6 Be sure that the Illuminator can move up and down vertically and right and left horizontally freely and smoothly without any tension 7 Replace the removed strap to the frame 8 Aft...

Страница 21: ...main body section of the Frame is fitted to your head securely after attaching the Strap to the Strap holder of the Frame 3 Adjust the position of Illuminator by moving it up and down to obtain the o...

Страница 22: ...e according to your preference and the procedure to be performed 2 Squeeze the stopper of Strap to fit the body section of Frame to your head securely 3 Adjust the position of Illuminator by moving it...

Страница 23: ...lace 5 4 2 Connecting Illuminator to Battery Pack 1 To connect the Cord to the Battery pack gasp the black rubber part of Light plug of Cord with fingers while holding the Battery pack as the Light ja...

Страница 24: ...tor is turned on and off repeatedly It is possible to pin the Middle switch on clothes by using the supplied Middle switch clip for your convenience To use the Clip remove the release paper on the Cli...

Страница 25: ...e illumination time decreases and the remaining available time of use becomes 30 35 and 50 minutes at the High Middle and Low brightness levels respectively the orange lamp will light When the availab...

Страница 26: ...lt available illumination time is reduced Replace all batteries with new ones Illuminator does not lighten even though the indicator for residual quantity light is lightened in green Illuminator is no...

Страница 27: ...optical grade cleaning solution 7 2 Tightening Screws When movement of a hinge part moves too freely or any connection part is loosened tighten up screws with Phillips screwdriver s which is supplied...

Страница 28: ...s in accordance with local regulations and or environmental guidelines to avoid bodily injury or infection since the cleaning materials may contain infectious matter 7 4 2 Rechargeable Battery All rec...

Страница 29: ...ing protrusions 72 5 65 20 mm 2 85 2 56 0 79 in Weight excluding batteries 70 g not including batteries Operation Time 4 hours at High mode 7 hours at Middle mode 17 hours at Low mode Rechargeable Bat...

Страница 30: ...ort s contact your local dealer or NEITZ located at the following address LOCAL DEALER Neitz Instruments Co Ltd 4F Ichibancho Court 15 21 Ichibancho Chiyoda ku Tokyo 102 0082 Japan Phone 81 3 3237 055...

Страница 31: ...ions below to take the appropriate measures Condition of the Battery Alarm Lamp Operational Illumination Depleted Illumination Green Lamp lit Green and Orange Lamp Lit Orange Lamp Blinking Green Lamp...

Страница 32: ...ce and Manufacturer s Declaration Electromagnetic Emissions Guidance and Manufacturer s Declaration Electromagnetic Emissions The NSI III is intended for use in the electromagnetic environment specifi...

Страница 33: ...2 6kV contact 8kV air 6kV contact 8kV air Floors should be wood concrete or ceramic tile If floors are covered with synthetic material the relative humidity should be at least 30 Electrical fast tran...

Страница 34: ...mitters as determined by an electromagnetic site survey a should be less than the compliance level in each frequency range b Interference may occur in the vicinity of equipment marked with the followi...

Страница 35: ...Transmitter m 150kHz to 80MHz 1 2 80MHz to 800MHz 1 2 800MHz to 2 5GHz 2 3 0 01 0 12 0 12 0 23 0 1 0 38 0 38 0 73 1 1 2 1 2 2 3 10 3 8 3 8 7 3 100 12 12 23 For transmitters rated at a maximum output p...

Страница 36: ...2 Japan Phone 81 3 3237 0552 Fax 81 3 3237 0554 e mail int neitz co jp URL http neitz ophthalmic com Distributed by TD11 12690001E 4 201903 Printed in Japan As part of our policy of continued product...

Отзывы: