Figure 3
Figure 4
HOW TO FILL THE GUN WITH A FILLER PUMP
Insert the gun filler nipple into the filler pump socket. Operate the filler pump to fill the container. Stop the
filler pump when the follower rod extends to approximately 8 inches (20 cm). (See Figure 4)
Push the follower rod into the grease tube assembly by pressing the locking lever.
HOW TO EXPEL AIR POCKETS
Withdraw the follower rod from the grease tube assembly cap and engage it with the follower by rotating
the follower handle. Exert force on the follower handle while holding down the vent valve.
Pull the trigger in short bursts to operate gun until trapped air is expelled. Disengage the follower rod from
the follower by rotating the follower handle. Push the follower rod into the grease tube assembly.
If step 2 fails, you can adjust the screw inside the grease release valve, then both grease and air will be
expelled.
ASSEMBLY AND MAINTENANCE NOTES
(see figures 5 and 6)
It is also normal for lithium ions batteries to gradually lose their power retention capacity over hundreds of
charge cycles. When this happens, replacement of the battery pack will be required.
The motor polarity is important, the positive (red wire) must be connected to the positive terminal on the
motor, which is identified with the small plastic dot next to it.
The green ground wire must be secured under the motor mounting screw.
ITEM
(1)
Battery
(2)
Battery Release Button
(3)
Handle Assembly
(4)
Trigger
(5)
Locking Button
(6)
Display
(7)
Grease Release Valve
(8)
Pump Assembly
(9)
Flexible Hose
(10) Grease Tube Assembly
(11) Grease Nipple Coupler
(12) Follower Handle
(13) Locking Lever
Figure 5
LCD Display
Grease
Release
Valve
Filler
Nipple
5