en
Troubleshooting
46
Fault
Cause and troubleshooting
E:32-00 will light up
alternately or indicator
for water supply lights
up.
5.
Remove the filter from the supply hose
6.
Clean the filter.
7.
Re-insert the filter in the supply hose.
8.
Screw the water connection back on.
9.
Check the water connection for leaks.
10.
Restore the power supply.
11.
Switch the appliance on.
E:34-00 will light up
alternately.
Water is continuously running into the appliance.
1.
Turn off the water tap.
2.
Call Customer Service →
E:61-02 will light up
alternately.
Not an appliance fault. Wastewater pump is blocked
or the cover of the wastewater pump is loose.
1.
Clean the wastewater pump.
"Clean wastewater pump", Page 51
2.
Secure the cover of the wastewater pump so it
clicks into position.