Troubleshooting
aus
45
Fault
Cause and troubleshooting
E:32-00 will light up
alternately or indicator
for water supply lights
up.
5.
Remove the filter from the supply hose
6.
Clean the filter.
7.
Re-insert the filter in the supply hose.
8.
Screw the water connection back on.
9.
Check the water connection for leaks.
10.
Restore the power supply.
11.
Switch the appliance on.
E:34-00 will light up
alternately.
Water is continuously running into the appliance.
1.
Turn off the water tap.
2.
Call Customer Service →
E:61-03 will light up
alternately. Water is
not drained.
Wastewater hose is blocked or kinked.
1.
Reposition the wastewater hose without kinks.
2.
Remove residues.
Siphon connection is still sealed.
▶
Check the connection to the siphon and open if ne-
cessary.
Cover of the wastewater pump is loose.
▶
Secure the cover of the Wastewater pump
→
E:61-02 will light up
alternately.
Wastewater pump is blocked.
▶
Clean the wastewater pump.
→
"Clean wastewater pump", Page 55
Cover of the wastewater pump is loose
▶
Secure the cover of the Wastewater pump
→
E:90-01 will light up
alternately.
Mains voltage is too low.
This is not a fault on the appliance.
1.
Contact an electrician.
2.
Have the mains voltage and electrical installation
checked by an electrician.