background image

15

Installation

The extractor hood

is designed for

installation on the kitchen ceiling or on a rigid
suspended ceiling.

During installation, optional accessories may

also require fitting.

Observe the minimum distance between

hob and extractor hood (see ”Safety
instructions”)!

Avoid damaging the sensitive surfaces!

Preparing the ceiling

RISK OF INJURY, 
DAMAGE TO PROPERTY

Before drilling the holes for the designated
installation location, check for concealed
electrical cables and other lines.

The ceiling must be level and horizontal.

The enclosed screws and wall plugs are

suitable for concrete and natural stone. Use the
appropriate fasteners for other ceiling
structures.
Ensure that the ceiling has adequate load
bearing capacity.

Ensure that the depth of the drilled holes

corresponds with the length of the screws.

Ensure that the wall plugs are secure.

Max. weight in kg: 50

Design subject to modification in line with
technical development.

Installing the upper support frame

1.

Specify the total height of the support
frame before installation and mark the
screw holes. The height of the support
frame can be adjusted in 20 mm steps.
The total height is measured from the
height of the ceiling, the height of the
worktop and the corresponding distances
between the hob and extractor hood.

2.

On the ceiling mark the centre point of the
extractor hood.

3.

Using the enclosed template, mark the
positions for the screws on the ceiling.

4.

Drill 4x 8 Ø mm holes and press in wall
plugs flush with the ceiling.

5.

Attach the upper part of the support frame
to the ceiling with 4 screws.

6.

Ensure that the support frame is in the
correct position. The middle bracket
defines the preferred side. It must be facing
the hob control.

Содержание I89E34N0GB

Страница 1: ...Installation instructions and how to use and look after your built in cooker hoods NEFF UK Ltd ...

Страница 2: ...Abb 1 ELECTRO Fig 1 GAZ 2 min 650 min 550 ...

Страница 3: ... installation 7 Operating modes 8 Exhaust air mode 8 Circulating air mode 8 Operation 9 Cleaning and Care 10 Removing and installing the grease filters 11 Removing and installing the metal mesh grease filters 11 Installing and removing the activated carbon filters 11 Changing the bulbs 12 Installation instructions 13 Connecting Pipes 13 Electrical Connections 14 Installation 15 Installation prepar...

Страница 4: ... hazardous for children Therefore keep them outside the reach of children Disposal of the old appliance Old appliances are not worthless rubbish Valuable raw materials can be reclaimed by recycling old appliances This appliance is identified according to the European Directive 2002 96 EC on waste electrical and electronic equipment WEEE The directive specifies the framework for an EU wide valid re...

Страница 5: ...ustomer service or a similarly qualified person to prevent hazardous situations Only a qualified technician may install including electrical connection service or repair the extractor hood Always isolate the extractor hood by pulling out the mains plug or switching off the fuse Safety instructions If the appliance is improperly installed serviced or repaired the user may be placed in considerable ...

Страница 6: ...obs observe the appropriate national statutory regulations e g in Germany Technische Regeln Gasinstallation TRGI Observe the currently valid installation regulations and instructions of the gas appliance manufacturer During installation ensure that only one side of the extractor hood is situated directly next to a high sided unit or a wall Otherwise there is a risk of heat build up The gap between...

Страница 7: ... food with oils or fats e g chips Overheated oils or fats can easily ignite A risk of fire can be prevented by cleaning the grease filters regularly and changing the activated carbon filter in good time Never operate the extractor hood without grease filters Correct installation Check the manufacturer s specifications for the cooker to determine whether an extractor hood can be operated over it If...

Страница 8: ...culating airmode The air which is drawn in is cleaned by the grease filters and an activated carbon filter and conveyed back into the kitchen An activated carbon filter must be installed to bind odours in circulating air mode see Removing and installing the grease filters The complete installation set as well as the replacement filters are available from specialist outlets customer service or the ...

Страница 9: ...tting 2 or 3 Switching off the fan Press button 0 Light The light can be switched on and off independently of the fan For appliances with Intensive setting The Intensive setting P generates maximum performance It can be used if thick fumes or strong odours occur temporarily 0 1 2 3 The description of the operation applies to several appliance models It is possible that individual features are desc...

Страница 10: ...ease particles from the kitchen fumes The filter mats consist of fire proof metal RISK OF FIRE As the filters become more saturated with greasy residue the flammability increases The function of the extractor hood may also be impaired The risk of fire is prevented by cleaning the metal mesh grease filters in good time When cleaning the grease filters also remove grease deposits from the accessible...

Страница 11: ...arbon filters must be replaced approximately 2x year The activated carbon filter is available from specialist outlets customer service or the Online Shop see Optional accessories Use original filters only Activated carbon filters do not contain any pollutants They can be disposed of in the household refuse Before removing and installing the grease filters always follow the instructions and warning...

Страница 12: ...tructions The description of changing the bulbs applies to several appliance models NOTE Observe the warranty regulations in the enclosed service booklet Changing the halogen bulbs Halogen bulbs become very hot during operation Even some time after the appliance has been switched off there is still a risk of burns Before changing the halogen bulbs ensure that they have cooled down fully 1 Carefull...

Страница 13: ... rough exhaust air pipes a lot of pipe bends or pipe diameters less than 150 mm are used the air capacity will be less than optimum and there will be an increase in noise Use only pipes or hoses made of non combustible material for installation of the exhaust air duct The manufacturer of the extractor hoods is not responsible for complaints which can be attributed to planning and design of the pip...

Страница 14: ...required connection data can be found on the rating plate inside the appliance when the grease filters have been removed Length of the power cord approx 1 30 m This extractor hood complies with the EC interference suppression regulations ELECTRICAL CONNECTION Before connecting the appliance to the power supply always follow the instructions and warnings in the chapter entitled Safety instructions ...

Страница 15: ...he drilled holes corresponds with the length of the screws Ensure that the wall plugs are secure Max weight in kg 50 Design subject to modification in line with technical development Installing the upper support frame 1 Specify the total height of the support frame before installation and mark the screw holes The height of the support frame can be adjusted in 20 mm steps The total height is measur...

Страница 16: ...must be facing the hob control NOTE The support frame can be aligned subsequently by loosening the fastening screws on the ceiling Installing the extractor hood 1 Hook the extractor hood from below into the support frame Do not trap the power cord 2 Attach the extractor hood to the support frame with 2 securing screws 3 Hook in retaining clip and screw tight 4 Connect the pipes 5 Connect the power...

Страница 17: ... flue ducts may have sharp edges We recommend wearing protective gloves during installation 1 Separate the flue ducts To do this remove the adhesive tape 2 Remove the protective film from both flue ducts 3 Attach both parts of the upper flue to the extractor hood und push together NOTE Protect the extractor hood from damage Avoid scratching the sensitive surfaces Installation ...

Страница 18: ...18 Notes ...

Страница 19: ...19 Notes ...

Страница 20: ...20 Notes ...

Страница 21: ...21 Notes ...

Страница 22: ...22 Notes ...

Страница 23: ...23 Accessories Z5134X5 Z5136X5 669648 281 ...

Страница 24: ...9000 416 279 Printed in Germany 0109 Es NEFF UK Ltd Grand Union House Old Wolverton Road Old Wolverton Milton Keynes MK12 5PT Tel 01908 328300 Fax 01908 328399 ...

Отзывы: