General information
General i
nformatio
n
Exhaust air mode
:
Warning
Risk of death!
Risk of poisoning from flue gases that are drawn back
in. The exhaust air must not be conveyed into a
functioning smoke or exhaust gas flue or into a shaft
which is used to ventilate installation rooms that contain
heating appliances. If the exhaust air is to be conveyed
into a non-functioning smoke or exhaust gas flue, you
must obtain the consent of the heating engineer
responsible.
If the exhaust air is conveyed through the outer wall, a
telescopic wall box should be used.
Exhaust duct
Note:
The device manufacturer does not assume any
warranty for complaints attributable to the pipe section.
■
The device achieves its optimum performance by
means of a short, straight exhaust air pipe and as
large a pipe diameter as possible.
■
As a result of long rough exhaust air pipes, many
pipe bends or pipe diameters that are smaller than
150 mm, the optimum extraction performance is not
achieved and fan noise is increased.
■
The pipes or hoses for laying the exhaust air line
must consist of non-combustible material.
Round pipes
An inner diameter of 150 mm, but at least 120 mm, is
recommended.
Flat ducts
The inner cross-section must correspond to the
diameter of the round pipes.
dia. 150 mm ca. 177 cm
2
dia. 120 mm ca. 113 cm
2
■
Flat ducts should not have any sharp deflections.
■
Use sealing strips for deviating pipe diameters.
Preparing the ceiling
■
The ceiling must be flat, horizontal and have
adequate load-bearing capacity.
■
The depth of the bore holes must be the same
length as the screws. The wall plugs must have a
secure grip.
■
The enclosed screws and wall plugs are suitable for
solid brickwork. Suitable fasteners must be used for
other structures (e.g. plasterboard, porous concrete,
poroton bricks).
■
The max. weight of the extractor hood is
50 kg
.
Electrical connection
:
Warning
Risk of electric shock!
Components inside the appliance may have sharp
edges. These may damage the connecting cable. Do
not kink or pinch the connecting cable during
installation.
The required connection data can be found on the
rating plate inside the appliance; to do this, remove the
metal mesh grease filter.
Length of the cable: approx. 1.30 m
This appliance complies with the EC interference
suppression regulations.
:
Warning
Risk of electric shock!
It must always be possible to disconnect the appliance
from the electricity supply. The appliance must only be
connected to a protective contact socket which has
been correctly installed. If the plug is no longer
accessible following installation of the appliance, or a
fixed connection is required, an all-pole isolating switch
must be present on the installation side with a contact
gap of at least 3 mm. The fixed connection must only
be installed by an electrician.