The extractor hood

is designed for

installation on the kitchen ceiling or on a rigid
suspended ceiling.

During installation, optional accessories may

also require fitting.

Observe the minimum distance between

hob and extractor hood (see ”Safety
instructions”)!

Avoid damaging the sensitive surfaces!

Preparing the ceiling

RISK OF INJURY, 
DAMAGE TO PROPERTY

Before drilling the holes for the designated
installation location, check for concealed
electrical cables and other lines.

The ceiling must be level and horizontal.

The enclosed screws and wall plugs are

suitable for concrete and natural stone. Use the
appropriate fasteners for other ceiling
structures.
Ensure that the ceiling has adequate load
bearing capacity.

Ensure that the depth of the drilled holes

corresponds with the length of the screws.

Ensure that the wall plugs are secure.

Max. weight in kg: 50

Design subject to modification in line with
technical development.

Installing the upper support frame

1.

Specify the total height of the support
frame before installation and mark the
screw holes. The height of the support
frame can be adjusted in 20 mm steps.
The total height is measured from the
height of the ceiling, the height of the
worktop and the corresponding distances
between the hob and extractor hood.

2.

On the ceiling mark the centre point of the
extractor hood.

3.

Using the enclosed template, mark the
positions for the screws on the ceiling.

4.

Drill 4x 8 Ø mm holes and press in wall
plugs flush with the ceiling.

5.

Attach the upper part of the support frame
to the ceiling with 4 screws.

6.

Ensure that the support frame is in the
correct position. The middle bracket
defines the preferred side. It must be facing
the hob control.

Содержание I71F45N0GB

Страница 1: ...Installation instructions and how to use and look after your built in cooker hoods NEFF UK Ltd...

Страница 2: ...Abb 1 ELECTRO Fig 1 GAZ 2...

Страница 3: ...nstallation 7 Operating modes 8 Exhaust air mode 8 Circulating air mode 8 Operation 9 Cleaning and Care 10 Removing and installing the grease filters 11 Removing and installing the metal mesh grease f...

Страница 4: ...hazardous for children Therefore keep them outside the reach of children Disposal of the old appliance Old appliances are not worthless rubbish Valuable raw materials can be reclaimed by recycling old...

Страница 5: ...stomer service or a similarly qualified person to prevent hazardous situations Only a qualified technician may install including electrical connection service or repair the extractor hood Always isola...

Страница 6: ...bs observe the appropriate national statutory regulations e g in Germany Technische Regeln Gasinstallation TRGI Observe the currently valid installation regulations and instructions of the gas applian...

Страница 7: ...if you are cooking food with oils or fats e g chips Overheated oils or fats can easily ignite A risk of fire can be prevented by cleaning the grease filters regularly and changing the activated carbo...

Страница 8: ...ulating airmode The air which is drawn in is cleaned by the grease filters and an activated carbon filter and conveyed back into the kitchen An activated carbon filter must be installed to bind odours...

Страница 9: ...ht can be switched on and off independently of the fan Intensive setting The Intensive setting generates maximum performance It can be used if thick fumes or strong odours occur temporarily Keep press...

Страница 10: ...ase particles from the kitchen fumes The filter mats consist of fire proof metal RISK OF FIRE As the filters become more saturated with greasy residue the flammability increases The function of the ex...

Страница 11: ...be replaced approximately 2x year The activated carbon filter is available from specialist outlets customer service or the Online Shop see Optional accessories Use original filters only Activated carb...

Страница 12: ...h the glass tube Therefore use a clean cloth when inserting the bulb 3 Close the inner frame of the halogen bulb NOTE The inner frame of the halogen bulb will not close unless it was fully opened befo...

Страница 13: ...ong rough exhaust air pipes a lot of pipe bends or pipe diameters less than 150 mm are used the air capacity will be less than optimum and there will be an increase in noise Use only pipes or hoses ma...

Страница 14: ...equired connection data can be found on the rating plate inside the appliance when the grease filters have been removed Length of the power cord approx 1 30 m This extractor hood complies with the EC...

Страница 15: ...he drilled holes corresponds with the length of the screws Ensure that the wall plugs are secure Max weight in kg 50 Design subject to modification in line with technical development Installing the up...

Страница 16: ...ust be facing the hob control NOTE The support frame can be aligned subsequently by loosening the fastening screws on the ceiling Installing the extractor hood 1 Hook the extractor hood from below int...

Страница 17: ...flue ducts may have sharp edges We recommend wearing protective gloves during installation 1 Separate the flue ducts To do this remove the adhesive tape 2 Remove the protective film from both flue duc...

Страница 18: ...18 Notes...

Страница 19: ...19 Notes...

Страница 20: ...20 Notes...

Страница 21: ...21 Notes...

Страница 22: ...22 Notes...

Страница 23: ...23 Accessories Z5134X5 Z5136X5 669648 281...

Страница 24: ...9000 414 743 Printed in Germany 0109 Es NEFF UK Ltd Grand Union House Old Wolverton Road Old Wolverton Milton Keynes MK12 5PT Tel 01908 328300 Fax 01908 328399...

Отзывы: