background image

11

en

Prior to installation

 

Round pipes:

 

We recommend

 

Internal diameter: 

150 mm

 (at least 120 mm).

 

Flat ducts 

must have an internal crosssection 

that equates to that of round pipes.

 

There should be no sharp bends.

 

ø 120 mm approx. 113 cm

2

 

ø 150 mm approx. 177 cm

2

 

If pipes have different diameters:

 Insert seal-

ing strip.

 

For exhaust-air mode,

 ensure that there is an 

adequate supply of fresh air.

Connecting a Ø 150 mm exhaust-air pipe:

 

Mount the pipe directly onto the air outlet on the 

hood.

Connecting a Ø 120 mm exhaust-air pipe:

 

Attach the reducing con-

nector directly to the air 

pipe.

 

Attach the exhaust-air 

pipe to the reducing con-

nector.

Circulating-air mode

 

With activated carbon filter if exhaust-air mode 

is not possible.

 

The complete installation set can 

be obtained 

from specialist

 outlets. 

The corresponding accessory numbers 

can be found at the end of these oper-

ating instructions.

Electrical connection

WARNING: THIS APPLIANCE MUST BE 

EARTHED
IMPORTANT: Fitting a Different Plug:

The wires in the mains lead are coloured in accord-

ance with the following code:
 

Green and Yellow  – Earth

 

Blue  

 

– Neutral

 

Brown    

– Live

If you fit your own plug, the colours of these wires 

may not correspond with the identifying marks on 

the plug terminals.
This is what you have to do:

1.  Connect the green and yellow (Earth) wire to 

the terminal in the plug marked ‘E’ or with the 

symbol ( ), or coloured green or green and yel-

low.

2.  Connect the blue (Neutral) wire to the terminal 

in the plug marked ‘N’ or coloured black.

3.  Connect the brown (Live) wire to the terminal 

marked ‘L’, or coloured red.

The extractor hood 

should only be connected to an 

earthed socket that has been installed according to 

relevant regulations.
If possible, site the earthed socket directly behind 

the chimney panelling.

 

The earthed socket should be connected via its 

own circuit.

 

If the earthed socket is no longer accessible fol-

lowing installation of the extractor hood, ensure 

that there is a permanently installed disconnec-

tor.

If it is necessary to wire the extractor hood di-

rectly into the mains:

The extractor hood should only be connected to the 

electricity supply by a properly qualified electrician.

A separator must be installed in the household 

circuit. A suitable separator is a switch that has a 

contact gap of more than 3 mm and interrupts all 

poles. Such devices include circuit breakers and 

contactors.

 

If the connecting cable for this appliance 

is damaged, the cable must be replaced by the 

manufacturer or his customer service or a similarly 

qualified person in order to prevent serious injury to 

the user.

Preparing the wall

 

The wall must be flat and perpendicular.

 

Ensure that the wall is capable of providing a 

firm hold for mounting screws and plugs.

Weight in kg: 20.

We reserve the right to construction changes within 

the context of technical development.

Содержание D96W44N0GB

Страница 1: ...auchs und Montageanleitung en Operating and installation instructions fr Notice de montage et d utilisation nl Gebruiks en montageaanwijzing it Istruzioni per l uso e l installatore es Instrucciones d...

Страница 2: ......

Страница 3: ...n conveyed back into the kitchen The grease filter absorbs the grease particles in the kitchen vapours The activated carbon filter binds the odorous substances If no activated carbon filter is install...

Страница 4: ...maximum setting if three or more gas hotplates are operated simultaneously Do not operate more than 2 gas cooking areas simultaneously over a period of max 15 minutes at maximum thermal load Due to th...

Страница 5: ...ed immediately to prevent the remaining bulbs from overloading Never operate the extractor hood without a grease filter Overheated fat or oil can easily catch fire If you are cooking with fat or oil e...

Страница 6: ...g vapours The filter mats are made from noncombustible metal Caution As the filter becomes more and more saturated with grease there is an increased risk of fire and the function of the extractor hood...

Страница 7: ...ed and must be replaced approximately every year of operation or more frequently with heavy usage Replacing the activated carbon filter Unhook the filter holding grid see Removing and inserting metal...

Страница 8: ...ning agent Do not use aggressive acidic or caustic clean ers Do not use abrasive agents Replacing the light bulbs 1 Switch off the extractor hood and pull out the mains plug or switch off the electric...

Страница 9: ...liance render it unusable You received your new appliance in a protective shipping carton All packaging materials are environ mentally friendly and recyclable Please contribute to a better environment...

Страница 10: ...r can flow through non lockable openings e g in doors win dows and via the airintake exhaust air wall box or by other technical measures such as reciprocal interlocking etc If the air intake is inadeq...

Страница 11: ...terminal in the plug marked E or with the symbol or coloured green or green and yel low 2 Connect the blue Neutral wire to the terminal in the plug marked N or coloured black 3 Connect the brown Live...

Страница 12: ...mney brackets 4 Insert plugs 11 into the holes A B and C so that they are flush with the wall 5 Fix the brackets 7 2 1 using the screws sup plied 6 Insert not totally the screw into the holes A Mounti...

Страница 13: ...ew Insert the connection extension pieces laterally 14 1 in connection 15 Make sure that the outlet of the extension pieces 14 1 is horizontally and vertically aligned with the chimney outlets Connect...

Страница 14: ...des to the brackets using the 4 screws 12c supplied Make sure that the outlet of the extensions pieces is aligned with the chimney outlets Lower Chimney Slightly widen the two sides of the Chimney and...

Страница 15: ...Z5137X5...

Страница 16: ...ichen uns 0 14 min DTAG Postfach 83 0101 Quellenstra e 2 Per Telefon D 81701 M nchen A 1100 Wien F r sterreich Fax 49 0 89 45 90 35 32 Fax 43 0 1 6 05 75 5 12 60 Tel 08 10 70 04 00 Internet www neff d...

Отзывы: