 Installation  

en

21

Wall-mounting the appliance and levelling it

1.

First remove the protective film from the back of the 

appliance and, following installation, remove the rest 

of the film.

2.

When mounting the appliance, ensure that it 

engages properly with the mounting supports.

3.

If required, the appliance can be moved to the right 

or to the left.

4.

Firmly tighten the screws for the mounting supports. 

Hold the bracket firmly when doing so. 

¨

5.

If no duct is to be fitted, screw in the two locking 

screws without the bracket. 

©

Connecting the pipes

If the extractor hood is to be operated in exhaust-air 

mode, the pipes must be connected. If the extractor 

hood is to be operated in air-recirculation mode, an 

optional accessory must be fitted. To do this, refer to 

the installation instructions provided.

Note: 

If an aluminium pipe is being used, smooth the 

connection area beforehand.

Exhaust air pipe, dia. 150 mm (recommended size)

Fit the exhaust air pipe directly to the air-pipe connector 

and seal the joint.

Exhaust air pipe, dia. 120 mm

1.

Fit the reducing connector directly to the air-pipe 

connector.

2.

Attach the exhaust air pipe to the reducing 

connector. 

3.

Use suitable means to seal both joints.

Attaching the flue duct

If the extractor hood is to be operated in exhaust-air 

mode, a flue duct must be fitted. 
The flue duct does not need to be fitted for air-

recirculation mode.

:

Warning

Risk of injury!

From sharp edges during installation. Always wear 

protective gloves while installing the appliance.

:

Warning

Risk of electric shock!

Components inside the appliance may have sharp 

edges. These may damage the connecting cable. Do 

not kink or pinch the connecting cable during 

installation.

1.

Separate the flue duct sections by removing the 

adhesive tape. 

2.

Remove the pieces of protective film from both flue 

duct sections.

3.

Push one flue duct section into the other.

Notes

– To prevent scratches, lay paper over the edges of 

the outer flue duct section to protect the surface.

– The slots of the inner flue duct section point 

downwards.

4.

Place flue ducts sections on the appliance.

5.

Slide the inner flue duct section upwards, attach it to 

the left and right sides of the retaining bracket, and 

then slide it down to engage it. 

¨

6.

Screw the flue duct section to the sides of the 

retaining bracket using two screws. 

©

7.

Clip the lower flue duct section in at the retaining 

bracket. The connection cable must not be 

damaged. 

ª

Note: 

If an air-recirculation optional accessory has been 

fitted and the extractor hood is to be operated without a 

flue duct, the cable must be wound onto the connector.

Содержание D95FRW1S0

Страница 1: ...en Instructions for installation and use Extractor hood...

Страница 2: ...s intended for domestic use and the household environment only The appliance is not intended for use outside Do not leave the appliance unattended during operation The manufacturer is not liable for d...

Страница 3: ...not exceed 4 Pa 0 04 mbar This can be achieved when the air needed for combustion is able to enter through openings that cannot be sealed for example in doors windows incoming exhaust air wall boxes o...

Страница 4: ...d by one of our trained after sales technicians If the appliance is defective unplug the appliance from the mains or switch off the circuit breaker in the fuse box Contact the after sales service Risk...

Страница 5: ...des Operatingmodes Exhaust air mode Note The exhaust air must not be conveyed into a functioning smoke or exhaust gas flue or into a shaft which is used to ventilate installation rooms which contain h...

Страница 6: ...an is switched off Touch the Q symbol Switching off Touch the Q symbol AirFresh function Switching on Touch the 3 symbol 3 will be shown on the display panel The fan runs for approximately 5 minutes p...

Страница 7: ...activated charcoal filter are is saturated the corresponding symbols will flash once the appliance has been switched off Metal grease filter Activated charcoal filter Metal grease filter and activate...

Страница 8: ...he 9 symbol This immediately stops fan run on Intensive setting You can use the intensive setting if there is a large build up of odours and fumes vapours Switching on Touch the symbol will light up o...

Страница 9: ...hed Saturation display If the metal grease filters or activated charcoal filter are is saturated the corresponding symbols will flash once the appliance has been switched off Metal grease filter Activ...

Страница 10: ...g directly 1 Press and hold the and symbols at the same time until the D and indicators start flashing 2 Confirm the connection on the hob within the next 30 seconds The extractor hood has been connec...

Страница 11: ...am cleaners Cleaning products that dissolve limescale Aggressive all purpose cleaning products Oven spray Note Wash new sponge cloths thoroughly before use Note Follow all instructions and warnings in...

Страница 12: ...rinse them thoroughly Leave the metal grease filters to drain on an absorbent material In the dishwasher Note Slight discolouration may occur if the metal grease filters are cleaned in the dishwasher...

Страница 13: ...appliance You can make a note of the numbers of your appliance and the telephone number of the after sales service in the space below to save time should it be required Please be aware that a visit b...

Страница 14: ...ilter for starter set Z51AIU0X0 Z51AIA0X0 Starter set for air recirculation mode angled hood without chimney Easy change filter for starter set Z51AIT0X0 Z51AIA0X0 Starter set for air recirculation mo...

Страница 15: ...to be operated in air recirculation mode an optional accessory must be fitted To do this refer to the installation instructions provided The flue duct does not need to be fitted for air recirculation...

Страница 16: ...rks perfectly at its installation location Caution Damage to the appliance The surfaces of the appliance are sensitive Avoid damaging them during installation The width of the extractor hood must corr...

Страница 17: ...l vacuum in the place where the heat producing appliance is installed does not exceed 4 Pa 0 04 mbar This can be achieved when the air needed for combustion is able to enter through openings that cann...

Страница 18: ...KGeneral information Generalinformation Checking the wall The wall must be level vertical and adequately load bearing The depth of the bore holes must be the same length as the screws The wall plugs m...

Страница 19: ...or hood should be positioned and lightly mark where the lower edge of the appliance should be on the wall Determine where the middle should be based on the hob Note We recommend fitting the extractor...

Страница 20: ...g without a flue duct Installation Screw in the mounting supports for the extractor hood until they are hand tight use a spirit level to level the appliance and then screw the mounting supports in ful...

Страница 21: ...ints Attaching the flue duct If the extractor hood is to be operated in exhaust air mode a flue duct must be fitted The flue duct does not need to be fitted for air recirculation mode Warning Risk of...

Страница 22: ...6...

Страница 23: ...6...

Страница 24: ...www neff international com 9001227077 9001227077 961509 Constructa Neff Vertriebs GmbH Carl Wery Stra e 34 D 81739 M nchen Register your product online...

Отзывы: