18

Connecting the pipes

Note: 

If using an aluminium pipe, smooth the 

connection area beforehand.

Exhaust-air pipe Ø 150 mm (recommended size)

Attach the exhaust-air pipe directly to the air-pipe 

connector and seal.

Exhaust-air pipe Ø 120 mm

1.

Attach the reducing connector directly to the air-pipe 

connector.

2.

Attach the exhaust air pipe to the reducing 

connector. 

3.

Seal both joints appropriately.

Attaching the flue duct

:

Warning – Risk of injury! 

Components inside the appliance may have sharp 

edges. Wear protective gloves.

1.

Separate the flue ducts. 

To do this, remove the adhesive tape.

2.

Remove the protective foil from both flue ducts.

3.

Push one flue duct into the other.

Notes

– To prevent scratches, lay paper over the edges of 

the lower flue duct to protect the surface.

– Slots of the inner flue duct point downwards.

4.

Place flue ducts on the appliance.

5.

Push the inner flue duct upwards and attach it to the 

fixing brackets on the left and right. 

¨

6.

Press the flue duct downwards until it engages. 

©

7.

Screw the flue duct to the sides of the fixing bracket 

using two screws. 

ª

[

$

%

&

Содержание D95BMP5N0B

Страница 1: ...en Instructions for installation and use EXTRACTOR HOOD...

Страница 2: ......

Страница 3: ...ion This appliance is intended for domestic use and the household environment only The appliance is not intended for use outside Do not leave the appliance unattended during operation The manufacturer...

Страница 4: ...dows incoming exhaust air wall boxes or by other technical means In any case consult your responsible Master Chimney Sweep He is able to assess the house s entire ventilation setup and will suggest th...

Страница 5: ...Do not use any high pressure cleaners or steam cleaners which can result in an electric shock Risk of electric shock Penetrating moisture may result in an electric shock Clean the appliance using a d...

Страница 6: ...onmentally friendly manner Operating modes OperatingmodesExhaust air mode Note The exhaust air must not be conveyed into a functioning smoke or exhaust gas flue or into a shaft which is used to ventil...

Страница 7: ...itching on Touch the 3 symbol 3 will be shown on the display panel The fan runs for approximately 5 minutes per hour at fan setting 1 Switching off Touch the 3 symbol This ends the AirFresh function I...

Страница 8: ...must be switched over accordingly The extractor hood must be connected and switched on Touch and hold the Q symbol and touch the or symbol until 2 lights up for air recirculation mode filters that can...

Страница 9: ...Aggressive all purpose cleaning products Oven spray Note Wash new sponge cloths thoroughly before use Note Follow all instructions and warnings included with the cleaning products Removing metal grea...

Страница 10: ...rinse them thoroughly Leave the metal grease filters to drain on an absorbent material In the dishwasher Note Slight discolouration may occur if the metal grease filters are cleaned in the dishwasher...

Страница 11: ...be replaced by the manufacturer their customer service or a qualified technician electrician only Warning Risk of injury The light emitted by LED lights is very dazzling and can damage the eyes risk g...

Страница 12: ...ance models It may be the case that an optional accessory that is listed does not apply for your appliance Note Observe the installation instructions in the accessory E no FD no After sales serviceO G...

Страница 13: ...that the appliance works perfectly at its installation location The surfaces of the appliance are easily damaged Avoid damaging them during installation The width of the extractor hood must correspon...

Страница 14: ...coming exhaust air wall box alone will not ensure compliance with the limit Safe operation is possible only when the partial vacuum in the place where the heat producing appliance is installed does no...

Страница 15: ...n Packaging material is dangerous to children Never allow children to play with packaging material KGeneral information GeneralinformationExhaust air mode Warning Risk of death Risk of poisoning from...

Страница 16: ...the electricity supply The appliance must only be connected to a protective contact socket that has been correctly installed The mains plug of the mains power cable must be easily accessible after ins...

Страница 17: ...appliance 1 First remove the protective foil from the back of the appliance and following installation remove the foil completely 2 When attaching the appliance ensure that it engages firmly with the...

Страница 18: ...Risk of injury Components inside the appliance may have sharp edges Wear protective gloves 1 Separate the flue ducts To do this remove the adhesive tape 2 Remove the protective foil from both flue duc...

Страница 19: ...6...

Страница 20: ...9001359200 9001359200 980615 en Valid within Great Britain Imported to Great Britain by BSH Home Appliances Ltd Grand Union House Old Wolverton Road Wolverton Milton Keynes MK12 5PT United Kingdom...

Отзывы: