background image

en

    Important safety information

12

Adequate incoming air must therefore 

always be ensured.

An incoming/exhaust air wall box alone will 

not ensure compliance with the limit.

Safe operation is possible only when the 

partial vacuum in the place where the heat-

producing appliance is installed does not 

exceed 4 Pa (0.04 mbar). This can be 

achieved when the air needed for combustion 

is able to enter through openings that cannot 

be sealed, for example in doors, windows, 

incoming/exhaust air wall boxes or by other 

technical means.

In any case, consult your responsible Master 

Chimney Sweep. He is able to assess the 

house's entire ventilation setup and will 

suggest the suitable ventilation measures to 

you.

Unrestricted operation is possible if the vapour 

extractor hood is operated exclusively in the 

circulating-air mode.

:

Warning – Danger of death! 

Risk of poisoning from flue gases that are 

drawn back in. If installing a ventilation system 

in a room with a heat-producing appliance 

connected to a chimney/flue, the electricity 

supply to the hood must be equipped with a 

suitable safety switch.

:

Warning – Risk of injury! 

Components inside the appliance may have 

sharp edges. Wear protective gloves.

Risk of injury! 

The appliance may fall down if it has not 

been properly fastened in place. All 

fastening components must be fixed firmly 

and securely.

Risk of injury! 

The appliance is heavy. To move the 

appliance, 2 people are required. Use only 

suitable tools and equipment.

Risk of injury! 

Changes to the electrical or mechanical 

assembly are dangerous and may lead to 

malfunctions. Do not make any changes to 

the electrical or mechanical assembly. 

:

Warning – Risk of electric shock! 

Components inside the appliance may have 

sharp edges. These may damage the 

connecting cable. Do not kink or pinch the 

connecting cable during installation.

Risk of electric shock! 

It must always be possible to disconnect 

the appliance from the power supply. The 

appliance must only be connected to a 

protective contact socket that has been 

correctly installed. If the plug can no longer 

be reached after installation, an energy-

isolating device in the phases must be 

provided in the permanent electrical 

installation in accordance with the 

installation regulations. The permanent 

electrical installation must only be wired by 

a professional electrician. We recommend 

installing a residual-current circuit breaker 

(RCCB) in the appliance's power supply 

circuit.

:

Warning – Risk of electric shock! 

Incorrect repairs are dangerous. Repairs may 

only be carried out and damaged power 

cables replaced by one of our trained after-

sales technicians. If the appliance is defective, 

unplug the appliance from the mains or switch 

off the circuit breaker in the fuse box. Contact 

the after-sales service.

:

Warning – Danger of suffocation! 

Packaging material is dangerous to children. 

Never allow children to play with packaging 

material.

Содержание D94ABC0N0B

Страница 1: ...en Instructions for installation and use Extractor hood...

Страница 2: ...on This appliance is intended for domestic use and the household environment only The appliance is not intended for use outside Do not leave the appliance unattended during operation The manufacturer...

Страница 3: ...n any case consult your responsible Master Chimney Sweep He is able to assess the house s entire ventilation setup and will suggest the suitable ventilation measures to you Unrestricted operation is p...

Страница 4: ...y high pressure cleaners or steam cleaners which can result in an electric shock Causes of damage Caution Risk of damage due to corrosion Always switch on the appliance while cooking to avoid condensa...

Страница 5: ...des OperatingmodesExhaust air mode Note The exhaust air must not be conveyed into a functioning smoke or exhaust gas flue or into a shaft which is used to ventilate installation rooms which contain he...

Страница 6: ...appliance using a damp cloth only Before cleaning pull out the mains plug or switch off the circuit breaker in the fuse box Warning Risk of electric shock Do not use any high pressure cleaners or stea...

Страница 7: ...m thoroughly Leave the metal grease filters to drain on an absorbent material In the dishwasher Note Slight discolouration may occur if the metal grease filters are cleaned in the dishwasher This disc...

Страница 8: ...es replaced by one of our trained after sales technicians If the appliance is defective unplug the appliance from the mains or switch off the circuit breaker in the fuse box Contact the after sales se...

Страница 9: ...ionalism of the manufacturer You can therefore be sure that the repair is carried out by trained service technicians who carry original spare parts for your appliances Accessories not included in the...

Страница 10: ...en Installation instructions 10 INSTALLATION INSTRUCTIONS Installation instructions Installationinstructions PLQ PLQ PLQ PLQ PLQ PLQ PLQ PLQ...

Страница 11: ...arance applies Risk of fire Grease deposits in the grease filter may catch fire Never work with naked flames close to the appliance e g flamb ing Do not install the appliance near a heat producing app...

Страница 12: ...y Risk of injury The appliance is heavy To move the appliance 2 people are required Use only suitable tools and equipment Risk of injury Changes to the electrical or mechanical assembly are dangerous...

Страница 13: ...power supply The appliance must only be connected to a protective contact socket that has been correctly installed If the plug can no longer be reached after installation an energy isolating device i...

Страница 14: ...en Installation 14 Installation 1 Attaching and aligning the appliance 2 Mark the hole for the safety screw 3 Remove the appliance once more...

Страница 15: ...Use sealing strips for deviating pipe diameters Connecting the appliance to the power supply Connecting the air extractor Note If using an aluminium pipe smooth the connection area beforehand 1 Attac...

Страница 16: ...FRP RQVWUXFWD 1HII 9HUWULHEV PE DUO HU 6WUD H 0 QFKHQ 9001272153 9001272153 970810 en Valid within Great Britain Imported to Great Britain by BSH Home Appliances Ltd Grand Union House Old Wolverton Ro...

Отзывы: