background image

en

    Important safety information

10

INSTALLATION INSTRUCTIONS

Installation instructions

This appliance is installed on the wall.

Follow the enclosed installation instructions for 

additional special accessories (e.g. for circulating-air 

mode).

The surfaces of the appliance are sensitive. Avoid 

damaging them during installation. 

(

Important safety 

information

Important

 safety i

nformatio

n

Read these instructions carefully. Only then 

will you be able to operate your appliance 

safely and correctly. Retain the instruction 

manual and installation instructions for future 

use or for subsequent owners.
The appliance can only be used safely if it is 

correctly installed according to the safety 

instructions. The installer is responsible for 

ensuring that the appliance works perfectly at 

its installation location.
The width of the extractor hood must 

correspond at least with the width of the hob.
For the installation, observe the currently valid 

building regulations and the regulations of the 

local electricity and gas suppliers.
When conveying the exhaust air, official and 

legal regulations (e.g. state building 

regulations) must be followed.

:

Warning

Risk of death!

Risk of poisoning from flue gases that are 

drawn back in. The exhaust air must not be 

conveyed into a functioning smoke or exhaust 

gas flue or into a shaft which is used to 

ventilate installation rooms that contain 

heating appliances. If the exhaust air is to be 

conveyed into a non-functioning smoke or 

exhaust gas flue, you must obtain the consent 

of the heating engineer responsible.

:

Warning

Danger of death!

Risk of poisoning from flue gases that are 

drawn back in.

Always ensure adequate fresh air in the room 

if the appliance is being operated in exhaust 

air mode at the same time as room air-

dependent heat-producing appliance is being 

operated.

PLQ
PP
PD[
PP

PLQ
PP

PP

PLQ
PP

PP

PP

!

!

[

[

[

[

[

[

[

[

[

Содержание D87ER22N0B/02

Страница 1: ...en Instructions for installation and use Extractor hood...

Страница 2: ...ocation This appliance is intended for domestic use and the household environment only The appliance is not intended for use outside Do not leave the appliance unattended during operation The manufact...

Страница 3: ...oming exhaust air wall boxes or by other technical means In any case consult your responsible Master Chimney Sweep He is able to assess the house s entire ventilation setup and will suggest the suitab...

Страница 4: ...les replaced by one of our trained after sales technicians If the appliance is defective unplug the appliance from the mains or switch off the circuit breaker in the fuse box Contact the after sales s...

Страница 5: ...ated carbon filter The different options for operating the appliance in circulating air mode can be found in the brochure Alternatively ask your dealer The required accessories are available from spec...

Страница 6: ...switch off the circuit breaker in the fuse box Warning Risk of electric shock Do not use any high pressure cleaners or steam cleaners which can result in an electric shock Warning Risk of injury Comp...

Страница 7: ...together with utensils Place the metal mesh grease filters loosely in the dishwasher The metal mesh grease filters must not be wedged in Removing metal grease filter 1 Open the lock and fold down the...

Страница 8: ...and wattage Note When inserting halogen bulbs do not touch the glass bulb Use a clean cloth to insert the halogen bulbs 1 Carefully remove the bulb ring using a suitable tool 2 Remove the bulb and rep...

Страница 9: ...ir is carried out by trained service technicians who carry original spare parts for your appliances Accessories for circulating air mode not included in the delivery Notes Follow the installation inst...

Страница 10: ...extractor hood must correspond at least with the width of the hob For the installation observe the currently valid building regulations and the regulations of the local electricity and gas suppliers W...

Страница 11: ...ance connected to a chimney flue the electricity supply to the hood must be equipped with a suitable safety switch Warning Risk of fire Grease deposits in the grease filter may catch fire The specifie...

Страница 12: ...of the round pipes dia 150 mm ca 177 cm2 dia 120 mm ca 113 cm2 Flat ducts should not have any sharp deflections Use sealing strips for deviating pipe diameters Checking the wall The wall must be leve...

Страница 13: ...extractor hood 2 Mark positions for the screws and the contour of the attachment area 3 Drill five 8 mm diameter holes to a depth of 80 mm for the attachments and press in the wall plugs flush with t...

Страница 14: ...connector and seal Exhaust air pipe 120 mm 1 Attach the reducing connector directly to the air pipe connector 2 Attach the exhaust air pipe to the reducing connector 3 Seal both joints appropriately A...

Страница 15: ...6...

Страница 16: ...www neff international com 9001028102 9001028102 961015 Constructa Neff Vertriebs GmbH Carl Wery Stra e 34 D 81739 M nchen Register your product online...

Отзывы: