background image

en

    Operating the appliance

6

Switching over the indicator for circulating-air mode

For circulating-air mode, the electronic control must be 

switched over accordingly:

The extractor hood must be connected and switched 

on.

Touch and hold the 

#

 and 

9

 symbols at the same 

time, until the 

’‹–

 indicator lights up for the 

circulating-air mode "Starter Set". Repeatedly 

pressing and holding this button combination 

causes the 

’–‘ 

 indicator to light up for the 

"CleanAir" circulating-air module.

Repeatedly pressing and holding this button 

combination switches the electronic control back 

over to ducted operation (

”‚–

 indicator).

Audible signal 

Switching on the audible signal

Touch and hold the 

 and + symbols at the same time 

for approximately three seconds when the fan is 

switched on. An audible signal sounds as an 

acknowledgement.

Switching off the acoustic signal

Repeat the "Switching on the acoustic signal" process.

Control panel model 2

Setting the fan

Switching on

Touch the 

#

 symbol.

The fan starts at setting 

ƒ

.

Touch + or - to alter the fan speed.

Switching off

Touch the 

#

 symbol.

Intensive setting

You can use the intensive setting if there is a large 

build-up of odours and fumes/vapours.
Touch the 

˜

 symbol. 

˜ƒ

 appears on the display. Touch 

the - symbol to switch back to the 

˜‚

 intensive setting.

After approximately six minutes, the electronics 

automatically reduce the fan to a lower setting . If you 

want to end the intensive setting before the preset time 

expires, touch the 

˜

 symbol.

Automatic mode

Switching on

Touch the 

#

 symbol.

The fan starts at setting 

ƒ

.

Touch the 

 symbol.

The optimum fan setting 

‘‚

‘ƒ

 or 

‘„

 is 

automatically set via a sensor.

Switching off

Touch the 

 or 

#

 symbol to switch automatic mode off.

The fan switches off automatically if the sensor no 

longer detects a change in the air quality of the room.
Automatic mode can run for a maximum of four hours.

Sensor control

In automatic mode, a sensor in the extractor hood 

detects the intensity of the cooking and roasting 

odours. Depending on the sensor setting, the fan 

automatically switches to another fan setting.
Default sensitivity setting: 

Lowest sensitivity setting: 

Highest sensitivity setting: 

Š

If the sensor control responds too quickly or too slowly, 

it can be changed accordingly:

1.

Press and hold the 

 symbol for approximately four 

seconds when the fan is switched on. The setting is 

displayed.

2.

The sensor control setting can be changed by 

touching the + or - symbol.

3.

To confirm the entry, press and hold the 

 symbol 

for approximately four seconds.

Explanation

#

Fan on/off

4

Noise reduction

3

AirFresh function

-

Reduces the fan settings

+

Increases the fan settings

˜

Intensive setting

Automatic function

6

Light on/off/dimming

Содержание D79MT86N1B

Страница 1: ... en Instructions for installation and use Extractor hood ...

Страница 2: ...g operation The manufacturer is not liable for damage which is caused by improper use or incorrect operation This appliance may be used by children over the age of 8 years old and by persons with reduced physical sensory or mental capabilities or by persons with a lack of experience or knowledge if they are supervised or are instructed by a person responsible for their safety how to use the applia...

Страница 3: ...te the appliance without the grease filter Risk of fire Grease deposits in the grease filter may catch fire Never work with naked flames close to the appliance e g flambéing Do not install the appliance near a heat producing appliance for solid fuel e g wood or coal unless a closed non removable cover is available There must be no flying sparks Risk of fire Hot oil and fat can ignite very quickly ...

Страница 4: ...slightly 1 slope 7Environmental protection Environmentalprotection Environmentally friendly disposal Dispose of packaging in an environmentally friendly manner ÇOperating modes Operatingmodes Exhaust air mode Note The exhaust air must not be conveyed into a functioning smoke or exhaust gas flue or into a shaft which is used to ventilate installation rooms which contain heat producing appliances Be...

Страница 5: ...y five minutes per hour Touch the 3 symbol if you want to end the AirFresh function Noise reduction function The noise reduction function reduces the fan noise Switching on Touch the 4 symbol This function is possible at all fan settings except fan setting This function also remains active after the fan is switched off Switching off Touch the 4 symbol Lighting The lighting can be switched on and o...

Страница 6: ...to switch back to the intensive setting After approximately six minutes the electronics automatically reduce the fan to a lower setting If you want to end the intensive setting before the preset time expires touch the symbol Automatic mode Switching on Touch the symbol The fan starts at setting ƒ Touch the symbol The optimum fan setting ƒ or is automatically set via a sensor Switching off Touch th...

Страница 7: ...and switched on Touch and hold the and symbols at the same time until the indicator lights up for the circulating air mode Starter Set Repeatedly pressing and holding this button combination causes the indicator to light up for the CleanAir circulating air module Repeatedly pressing and holding this button combination switches the electronic control back over to ducted operation indicator Audible ...

Страница 8: ...s place the other hand under the metal grease filter 2 Take the metal grease filter out of the holder For edge extraction filters pull the metal grease filter downwards While doing this place the other hand under the metal grease filter For additional filters open the lock and fold down the metal grease filter While doing this place the other hand under the metal grease filter Notes Grease can acc...

Страница 9: ...hen inserting halogen bulbs do not touch the glass tube Use a clean cloth to insert the halogen bulbs 1 Carefully remove the bulb ring using a suitable tool 2 Pull out the bulb and replace it with a bulb of the same type 3 Insert the bulb cover 4 Insert the mains plug or switch on the fuse again LED lights Defective LED lights may be replaced by the manufacturer their customer service or a qualifi...

Страница 10: ...air is carried out by trained service technicians who carry original spare parts for your appliances Accessories for circulating air mode not included in the delivery Notes Follow the installation instructions supplied with the accessories For appliances with an additional internal filter only the CleanAir recirculation module can be used Basic equipment Starter set for circulating air mode narrow...

Страница 11: ... extractor hood must correspond at least with the width of the hob For the installation observe the currently valid building regulations and the regulations of the local electricity and gas suppliers When conveying the exhaust air official and legal regulations e g state building regulations must be followed Warning Risk of death Risk of poisoning from flue gases that are drawn back in The exhaust...

Страница 12: ...ney flue the electricity supply to the hood must be equipped with a suitable safety switch Warning Risk of fire Grease deposits in the grease filter may catch fire The specified safety distances must be observed in order to prevent an accumulation of heat Observe the specifications for your cooking appliance If gas and electric hobs are operated together the largest specified distance applies Only...

Страница 13: ...150 mm ca 177 cm2 dia 120 mm ca 113 cm2 Flat ducts should not have any sharp deflections Use sealing strips for deviating pipe diameters Checking the wall The wall must be level vertical and adequately load bearing The depth of the bore holes must be the same length as the screws The wall plugs must have a secure grip The enclosed screws and wall plugs are suitable for solid brickwork Suitable fas...

Страница 14: ... extractor hood 2 Mark positions for the screws and the contour of the attachment area 3 Drill five 8 mm diameter holes to a depth of 80 mm for the attachments and press in the wall plugs flush with the wall Installation 1 Screw on the fixing bracket for the flue duct 2 Screw on brackets for the extractor hood hand tight Do not firmly tighten the screws 3 Screw in the threaded bolt leaving it prot...

Страница 15: ...connector and seal Exhaust air pipe Ø 120 mm 1 Attach the reducing connector directly to the air pipe connector 2 Attach the exhaust air pipe to the reducing connector 3 Seal both joints appropriately Attaching the flue duct Warning Risk of injury From sharp edges during installation Always wear protective gloves while installing the appliance 1 Separate the flue ducts To do this remove the adhesi...

Страница 16: ...www neff international com 9001018236 9001018236 941201 Constructa Neff Vertriebs GmbH Carl Wery Straße 34 D 81739 München Register your product online ...

Отзывы: