10

INSTALLATION INSTRUCTIONS

Installation instructions

Installat

ion instr

uctions

This appliance is installed on the wall.

Follow the enclosed installation instructions for 

additional special accessories (e.g. for circulating-air 

mode).

The surfaces of the appliance are sensitive. Avoid 

damaging them during installation. 

(

Important safety 

information

Important

 safety i

nformatio

n

Read these instructions carefully. Only then 

will you be able to operate your appliance 

safely and correctly. Retain the instruction 

manual and installation instructions for future 

use or for subsequent owners.
Check the appliance for damage after 

unpacking it. Do not connect the appliance if it 

has been damaged in transport.
The appliance can only be used safely if it is 

correctly installed according to the safety 

instructions. The installer is responsible for 

ensuring that the appliance works perfectly at 

its installation location.

Caution!

Damage to the appliance

The surfaces of the appliance are sensitive. 

Avoid damaging them during installation.
The width of the extractor hood must 

correspond at least with the width of the hob.
For the installation, observe the currently valid 

building regulations and the regulations of the 

local electricity and gas suppliers.

:

Warning – Risk of fire! 

Fatty deposits in the grease filter may catch 

fire. The specified safety clearances must 

be complied with in order to prevent a build-

up of heat. Refer to the information 

provided for your cooker. If gas and electric 

hobs are being operated together, the 

largest specified clearance applies.

Risk of fire! 

Grease deposits in the grease filter may 

catch fire. Never work with naked flames 

close to the appliance (e.g. flambéing). Do 

not install the appliance near a heat-

producing appliance for solid fuel (e.g. 

wood or coal) unless a closed, non-

removable cover is available. There must 

be no flying sparks.

When conveying the exhaust air, official and 

legal regulations (e.g. state building 

regulations) must be followed.

•

•

PLQ

[

[

[

[

[

[

Содержание D62PBC0N0B

Страница 1: ...en Instructions for installation and use Extractor hood...

Страница 2: ...tion This appliance is intended for domestic use and the household environment only The appliance is not intended for use outside Do not leave the appliance unattended during operation The manufacture...

Страница 3: ...n any case consult your responsible Master Chimney Sweep He is able to assess the house s entire ventilation setup and will suggest the suitable ventilation measures to you Unrestricted operation is p...

Страница 4: ...y high pressure cleaners or steam cleaners which can result in an electric shock Causes of damage Caution Risk of damage due to corrosion Always switch on the appliance while cooking to avoid condensa...

Страница 5: ...des Operatingmodes Exhaust air mode Note The exhaust air must not be conveyed into a functioning smoke or exhaust gas flue or into a shaft which is used to ventilate installation rooms which contain h...

Страница 6: ...he appliance using a damp cloth only Before cleaning pull out the mains plug or switch off the circuit breaker in the fuse box Warning Risk of electric shock Do not use any high pressure cleaners or s...

Страница 7: ...m thoroughly Leave the metal grease filters to drain on an absorbent material In the dishwasher Note Slight discolouration may occur if the metal grease filters are cleaned in the dishwasher This disc...

Страница 8: ...es replaced by one of our trained after sales technicians If the appliance is defective unplug the appliance from the mains or switch off the circuit breaker in the fuse box Contact the after sales se...

Страница 9: ...find the contact data of all countries in the enclosed customer service list To book an engineer visit and product advice Rely on the professionalism of the manufacturer You can therefore be sure tha...

Страница 10: ...rfectly at its installation location Caution Damage to the appliance The surfaces of the appliance are sensitive Avoid damaging them during installation The width of the extractor hood must correspond...

Страница 11: ...boxes or by other technical means In any case consult your responsible Master Chimney Sweep He is able to assess the house s entire ventilation setup and will suggest the suitable ventilation measure...

Страница 12: ...s The maximum weight of the extractor hood is 40 kg Electrical connection Warning Risk of electric shock Components inside the appliance may have sharp edges These may damage the connecting cable Do n...

Страница 13: ...plugs flush with the wall 4 Screw on the fixing bracket for the flue duct 5 Screw in 2 securing screws with washers to approx 5mm Installation 1 Attaching and aligning the appliance 2 Mark the hole fo...

Страница 14: ...iameters Connecting the appliance to the power supply Connecting the air extractor Note If using an aluminium pipe smooth the connection area beforehand 1 Attach the air extractor pipe directly to the...

Страница 15: ...6...

Страница 16: ...FRP RQVWUXFWD 1HII 9HUWULHEV PE DUO HU 6WUD H 0 QFKHQ 9001272149 9001272149 970103 en Valid within Great Britain Imported to Great Britain by BSH Home Appliances Ltd Grand Union House Old Wolverton Ro...

Отзывы: